Establishing a boiler water treatment plan will provide you with real-time feedback of your boiler system so you can get ahead of any issues that might occur as a result of poor water quality. We broke down the boiler water treatment process into three simple steps that you can incorporate into your preventative maintenance practices.
Steam boilers use a contained heat system to generate steam. The steam travels through pipes in the building’s walls where they emerge at radiators in heating systems. The radiators warm from the steam’s heat. As the steam gives off its heat, it condenses back to liquid water and returns to the tank. A boiler system of this type that does not allow outside water sources is a closed system and is highly efficient for using all the condensed water. An open network may be required in operations where the steam or water gets contaminated in such a way that it cannot return to the boiler for reuse.
A condensing boiler can condense the water vapour in the flue gases and withstand the corrosive and acidic qualities of the flue gas condensate. Although most boilers can condense the flue gasses, only boilers that have heat exchangers constructed from materials able to withstand the corrosion should be used in condensing application. Condensing boilers with primary and secondary heat exchanger do not work well as they are not able to fully condense and defeat the purpose of using a condensing boiler. Also, boilers with this arrangement are prone to condensation in the primary heat exchanger at lower firing rate which can cause damage to the heat exchanger.
As their name implies, hot water boilers operate by being completely filled with hot water. On the other hand, steam boilers are usually only filled approximately 3/4th of the way full, while the top quarter is reserved for steam.
The automatic boiler water level controller is mainly composed of hardware and software parts to complete the functions of the control system. The hardware part is mainly composed of the water level detection circuit, drive circuit, water level indication circuit, pressure automatic control simulation, manual control, etc. The software part is mainly composed of the programs written in assembly language.
If the impurities in the boiler feedwater are not dealt with properly, carryover of boiler water into the steam system can occur. This may lead to problems elsewhere in the steam system, such as:
The quality of boiler feedwater is an important determinant of safe boiler operations and it should be monitored to maintain the quality within safe working limits. Boiler feedwater is treated to protect the boiler from two basic problems: the buildup of solid deposits on the interior or water side of the tubes, and corrosion.
The vertical type and horizontal type are the two main types of boiler. The vertical gas-fired boiler has small volume and is suitable for small workshops or small production enterprises. It is often used in the fields of hot water and heating. The horizontal gas-fired boiler has larger volume with a wider application range than the vertical gas-fired boiler.