  • Why gas-fired hot water boilers require the softened water? 2020-11-27
    Gas-fired hot water boilers require high-quality water to improve the boiler performance and extend the service life. If the boiler uses the tap water of water which contains a lot of impurities, magnesium and calcium ions in the water will form white precipitates when the water is heated at high temperatures, which can cause the scaling problem to reduce the heat transfer efficiency of the boiler and bring hidden dangers of the boiler safety.
  • How to control the water content and calorific value in the combustion process of oil-fired boiler? 2020-08-07
    There are many skill indicators involved in the operation of oil-fired boiler, some of which are variables. We must master the relationship between variables and working effect of oil-fired boiler to realize better regulation.
  • What is the difference between gas-fired boiler and condensing gas-fired boiler in working principle? 2020-07-10
    In general, gas-fired boiler uses natural gas to heat water in order to provide heat source for underfloor heating and heating radiator, while condensing gas-fired uses condensation technology to recycle the thermal energy from the exhaust gas.
  • What are the discharge methods for industrial boilers? 2020-06-26
    Industrial boilers will produce wastes that needs to be treated during the use process, which is what we mentioned of boiler blowdown. What are the methods for boiler blowdown? 1. Regular blowdown 1) The time interval and quantity of discharge depend on the test results of boiler water. It usually do not exceed 5% of the water supply. 2) When the regular blowdown is being made under high load of the boiler, the blowdown of the water-cooled wall header is generally not required to avoid affecting the normal water circulation of the water-cooled wall and forming a tube explosion incident. 2. Continuous blowdown The amount of blowdown shall be determined according to the test results of the boiler water, and shall be completed by adjusting the needle-shaped angle of the blowdown tube.
  • How much coal is required to boil water from 60℃ to 90℃ in boiler 2020-05-22
    It could also say, how much heat is required to rais the water temperature from 60 ℃ to 90 ℃. To calculate heat required follow below steps Q= mCp dt Where m - water flow rate (kg/hr) Cp- specific heat of water dt- temperature differences ( 90–60) You will get heat required in kcal/ hr. dividing to Q by fuel GCV and system efficiency you will come to know how much fuel (either it is coal or oil) required to raise the temperature of water from 60 ℃ to 90℃.
  • What is the requirement of the control system of a coal-fired steam boiler ? 2020-05-15
    The coal-fired steam boiler is a forced circulation high-pressure single-tube DC boiler. Its operation process includes three processes: the combustion process of the fuel, the heat transfer process of flue gas to water and the vaporization process after water absorbs heat. In order to better control these different processes, the control system should make the heat of pulverized coal combustion adapt to the requirements of steam load changes and dryness.
  • What is the calculation method of the circulating water volume of a coal-fired hot water boiler? 2020-04-10
    The coal-fired boiler refers to the boiler uses various types of coal as fuel and converts the heat of coal to steam or hot water. There are generally two calculation methods of the circulating water volume of a coal-fired hot water boiler. One is to calculate the hourly water volume of one square meter and the other is to calculate the design parameter volume of every ton. As for the make-up water volume of this type of boiler, it is usually calculated as 1% to 3% of its total circulating water.
  • What is the reason that the pump of a biomass-fired is not pumping water? 2020-02-28
    1. If there is air in the pump or suction pipe, the air should be discharged. 2. If the depth of the bottom valve immersed in the water is not deep enough, the depth should be increased. 3. If the rotational speed is too slow or the conveyor belt is too loose, the rotational speed should be adjusted and the conveyor belt should be tightened. 4. If the impeller, suction pipe and bottom valve are blocked by dirt, you should check the pump body and clean the dirt. 5. If the height of water conveyance exceeds the regulations too much, the pump head should be adjusted to the specified range.