Gas-fired boiler is a kind of thermal equipment that uses the thermal energy released by fuel combustion or other thermal energy to heat the medium to the rated temperature. With the strict environmental protection, gas-fired boilers are widely used in power generation, heating, factory processing and so on. Boiler thermal power refers to the continuous heat production per unit time of hot water boiler at rated parameters, rated flow, designed fuel and guaranteed efficiency. So how to convert th...
Combustion system: The combustion system of coal-fired thermal oil heater includes base, grate, furnace, etc. The combustion system of oil/gas heat-conducting oil boiler includes furnace, burner, ignition device, etc.
Oil circulation system: circulating oil pump, oil injection pump, storage tank, expansion tank, etc.
Control system: complete with boiler control box.
Air-smoke system: refers to the system composed of flue gas and air generated by combustion, mainly including induced draft fans...
As we all know, the transportation cost is generally related to the weight of the boiler, so how much does a 4-ton boiler weigh? How much steel does it contain? According to the fuel, 4-ton boilers are divided into 4-ton gas-fired boilers and 4-ton coal-fired and biomass-fired boilers. The amount of steel used for small-scale coal-fired and biomass-fired boilers is generally 5-7 times of the boiler output (excluding the front and rear arches), and about 25 tons for 4-ton boilers.
Heat exchange station and gas boiler room are completely different individuals. Gas-fired boiler room is a place where water (or other medium) is heated with fuel to certain parameters. Gas-fired boiler room is a place where heat source is produced. Its main equipment includes boiler, blower, induced draft fan, circulating pump, and various auxiliary equipment (water treatment), among which boiler is the main part.
The purpose of the heat exchange station is to convert the high-temperature hot ...
The principle of boiler economizer is that the flue gas from the boiler tail enters the boiler economizer, and the water in the boiler economizer absorbs the temperature in the flue gas through the finned tube and then returns to the boiler, which is equivalent to raising the boiler feed water temperature and reducing the energy consumption when the boiler output is certain.
Boiler economizer is generally installed at the tail of boiler flue. Due to the different principles and boiler equipment...
The boiler needs to blow off every day, and it is advisable to reduce the blowdown to below the boiler water level every time.
The boiler water level meter can record the boiler water level in detail, and the water level has a great influence on the boiler, so we should ensure that the boiler water level is within the normal range.
When the gas-fired boiler is running, there will be pressure inside, which can provide sufficient power for all kinds of production equipment. However, if the press...
Modular gas-fired boiler, according to the user's load and design needs, combines several independently operating module units into an integral boiler. By monitoring and calculating the changes of indoor and outdoor temperature and temperature of supply and return water, the computer automatic control system can control each level of modules, automatically adjust the number of modules to start and stop, make the output heat always match the actual required heat load, and ensure that each module ...
Boiler output refers to the maximum continuous output of the boiler under rated parameters (pressure, temperature) and certain efficiency. For steam boilers, it is called rated evaporation, and the unit is tons/hour; For hot water boilers, it is called rated heat production, and the unit is MW.
What are the main factors affecting the output of gas-fired boilers? According to the analysis of ZOZEN Boiler engineers, there are many reasons for the insufficient output of gas-fired boilers,
...