  • What if the electric current of circulating pump thermal oil heater is lower than normal value? 2023-05-12
    If the electric current of the circulating pump in a thermal oil heater is lower than the normal value, it may indicate a problem with the pump or the system. Here are some potential causes and solutions: 1. Low fluid level: If the thermal oil level is low, the pump may not be able to circulate the oil properly, leading to lower current readings. Check the fluid level and add more oil if necessary. 2. Clogged filter: A clogged filter can restrict the flow of thermal oil, causing the pump to wo...
  • Are there any emissions, including smoke, produced by biomass boilers? 2023-05-05
    Biomass boilers do produce emissions when they burn organic materials such as wood chips, pellets, or agricultural waste. The exact type and amount of emissions depend on various factors such as the type of fuel used, combustion efficiency, and air pollution control technologies in place. However, with proper design and operation, biomass boilers can emit significantly less pollutants than traditional fossil fuel boilers, making them a more environmentally friendly option for heat and power...
  • What are the contents of boiler external inspection? 2023-04-28
    During the inspection, the management personnel of the boiler using unit and the monitor of the stoker shall be present to assist in the inspection and provide other materials required by the inspector.
  • What are the causes of and solutions to false water level in steam boiler? 2023-04-27
    The water level of steam drum can reflect the condition between feedwater quantity and evaporation quantity of boiler. If the two parameters maintain a stable balance, the water level also remains unchanged; otherwise, the water level will rise or fall. Besides, there is also a false water level phenomenon. How do we understand the false water level?
  • What is the load tracking of an industrial boiler? 2023-04-27
    Load tracking is an important feature of industrial boilers that helps to optimize their performance and efficiency. Load tracking refers to the ability of a boiler to adjust its output in response to changes in demand.   In an industrial setting, the demand for steam or hot water can vary significantly depending on factors such as production schedules, weather conditions, and other variables. Load tracking allows the boiler to adjust its output to match the changing demand, ensuring that...
  • What are the shutdown steps for the coal-fired steam boiler? 2023-04-27
    Proper shutdown procedures are crucial for ensuring the safe and efficient operation of a coal-fired steam boiler. The following steps should be followed when shutting down a coal-fired steam boiler: 1. Reduce the load: Before shutting down the boiler, the load should be reduced to its minimum level. This will help to prevent sudden drops in pressure and temperature, which could cause damage to the boiler and its components. 2. Shut off the fuel supply: The fuel supply to the boiler should be ...
  • What causes high exhaust temperature of biomass-fired boilers? 2023-04-27
    High exhaust temperature in a biomass-fired boiler can be caused by several factors, including: 1. Insufficient air supply: If there is not enough air supplied to the combustion chamber, the fuel may not burn completely, resulting in high exhaust temperatures. 2. Excessive fuel supply: Excessive fuel supply can overload the boiler, causing incomplete combustion and high exhaust temperatures. 3. Improper combustion: Improper combustion can lead to incomplete fuel burning and high exhaust tempe...
  • What if biomass-fired boiler furnace wall cracks, deformation, coking, and tilt, loose bricks, tube wall was totally stuck and rock wool sealing is burned out & combustion chamber wall is damaged? 2023-04-27
    A biomass-fired boiler furnace that has multiple issues such as wall cracks, deformation, coking, and tilt, loose bricks, tube wall blockage, burned-out rock wool sealing, and combustion chamber wall damage requires immediate attention to prevent further damage and potential safety hazards.   Firstly, it is recommended to shut down the boiler immediately to prevent any further damage and ensure the safety of the surrounding area. The boiler should not be restarted until all necessary repa...