“purchase gas fired boiler”- related faq

  • How to pick the right boiler for your needs? 2019-10-18
    There are so many options to weigh when looking for high efficiency boilers: hot water or steam, wetback or dryback, type of fuel, and more. However, there are a few key considerations to make when evaluating a new boiler for efficiency that will help you no matter what your other considerations may be. Look for a fan that can deliver a stable air supply, a burner and boiler unit that can produce low emissions, a design that maximizes flue gas velocity, smart pressure vessel design, and an efficient heating power to boiler surface ratio are just a few considerations to keep in mind. These simple but powerful design elements are hallmarks of solid construction and will add up to significant performance enhancements. Our team members are always available for consultation and can make specific recommendations when it comes to models once we know more about your needs.
  • Why Does My Business Need a Low NOx Boiler? 2019-08-16
    Today's businesses, regardless of industry, can always do more to improve their sustainability and limit the negative impact their actions have on the environment. There are a number of ways to do this, but one of the best is to use a boiler that's designed to limit the emissions of NOx — one of the most harmful greenhouse gases humans emit into the atmosphere. Aside from being good for the environment, a low NOx boiler can also be good for business.
  • What is a fire tube steam boiler? 2019-07-05
    A fire tube steam boiler is a boiler where the combustion gases from the burner are channeled through tubes that are surrounded by the fluid to be heated. The boiler body is the pressure vessel and contains the fluid. In most cases, this fluid is water that will circulate for heating purposes or become steam for use in processing. Each set of tubes through which the combustion gas passes, before making a turn, is considered a "step". Consequently, a three-step boiler will have three sets of pipes with the outlet located at the rear of the boiler.
  • How does a water tube steam boiler work? 2019-07-05
    In a water tube steam boiler, unlike a fire tube, water circulates inside the tubes. The heat that is generated and the combustion gases that surround the tubes heat the water that circulates inside them. Many water-tube boilers operate according to the principle of natural water circulation. The capacity of this type of boiler can be enhanced by increasing the number of tubes in the boiler.
  • There is hammer sound, vibration and unstable pressure during the operation of thermal oil heater. 2018-07-12
    (Question details) Specific performance:There is hammer sound in the oil inlet pipe, and the pointer of the inlet and outlet pressure gauge fluctuates.Answers: Cause of failure:The system contains gas and moisture.Troubleshooting:(1) Exhaust air.(2) Cook oil.
  • What is the reason for pump in the gas-fired boiler does not transfer oil? 2018-07-12
    Question details (performance):A pump in a gas boiler does not transfer oil. Answer: Fault reason:(1) Pump failure.(2) Oil pressure and power are reduced.(3) The oil inlet valve is not sealed.(4) The inlet pipe is not sealed.(5) The interceptor valve is closed.(6) The filter is contaminated.(7) The filter is not sealed.(8) The tubing is not sealed.(9) Pump suck air inlet.(10) The vacuum degree in oil tube is too high.Troubleshooting:(1) Replace with new pump.(2) Remove the inlet valve and clean or replace it.(3) Seal the inlet pipe.(4) Open.(5) Cleaning.(6) Replace the sealing ring.(7) Tighten and exhaust.(8) Clean the filter and valve.
  • What causes the burner motor of the gas-fired boiler running and ignition is normal, but then stop by failure? 2018-07-12
    Question details (performance):The burner motor of the gas boiler is running and the ignition is normal, but it is stopped by failure. Answer: Fault reason:The solenoid valve is not opened because the solenoid valve coil is damaged or the cable is broken. Troubleshooting:Replace solenoid valve or fix circuit failure, check voltage on terminal.