  • How to test your boiler's energy efficiency? 2024-02-02
    Testing a boiler's energy efficiency is essential for identifying how well it converts fuel into heat and for determining potential areas for improvement. As a professional industrial boiler manufacturer, ZOZEN Boiler emphasizes the importance of regular efficiency assessments to optimize performance, reduce fuel consumption, and minimize environmental impact. Here's a comprehensive approach to testing your boiler's energy efficiency: 1. Understand Key Efficiency RatingsAnnual Fuel Utilization ...
  • What is the heating load of an industrial boiler? 2024-01-19
    The heating load of an industrial boiler refers to the amount of energy required to generate a certain amount of heat in a specific period, usually measured in British Thermal Units (BTUs) per hour, kilowatts (kW), or megawatts (MW). Essentially, it's the amount of energy needed to heat the water or generate steam in the boiler for industrial processes or heating purposes. Understanding the heating load is crucial for several reasons: Boiler Sizing: Accurately determining the heating load is e...
  • Why industrial hot oil heating systems should be more commonly used than steam boilers? 2024-01-05
    ZOZEN Boiler is uniquely positioned to offer insights into the advantages of each system and help customers make informed decisions based on their specific needs. ZOZEN's Steam Boilers: Versatility and Efficiency: ZOZEN's steam boilers are known for their versatility and efficiency. They are ideal for a wide range of industrial applications where steam is required for both heating and process purposes.Advanced Technology: Incorporating the latest technology, these boilers offer high efficiency...
  • Why doesn't the gas boiler's motor turn on after pressing the start button? 2023-11-24
    (Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
  • What are the environmental protection checkpoints for boilers? 2023-10-13
    The importance of boilers in numerous industries cannot be overstated. However, in an age of increasing environmental consciousness, adhering to environmental protection standards for boiler operation is imperative. These checkpoints ensure that boilers operate with the least possible adverse impact on the environment. ZOZEN, as a globally recognized leader in boiler manufacturing and services, has always prioritized environmental standards, integrating them seamlessly into its professional offe...
  • What is conduction oil/ hot oil / heat transfer fluid? 2023-09-01
    Conduction oil, commonly known as hot oil or heat transfer fluid, is an integral component in a broad range of industrial applications that require the transfer of thermal energy. This specialized fluid functions as an intermediary that carries heat from one point to another within a closed-loop system, ensuring the even distribution of heat across various machinery and equipment. Often, these oils are utilized in industries such as chemical processing, petrochemical plants, and manufacturing to...
  • How often should steam boilers be serviced? 2023-08-11
    Typically, a steam boiler should receive servicing at least once per year. Any kind of safety failure with a boiler can have serious consequences, and so a yearly inspection will help to spot any safety issues that need to be addressed. Servicing your boiler on a regular basis can also help you to save money on repairs. If you spot a problem during routine maintenance, there's a good chance you'll be able to fix it at a much cheaper cost than if the problem goes unnoticed and becomes a larger and more serious issue.
  • What are the causes of and solutions to false water level in steam boiler? 2023-04-27
    The water level of steam drum can reflect the condition between feedwater quantity and evaporation quantity of boiler. If the two parameters maintain a stable balance, the water level also remains unchanged; otherwise, the water level will rise or fall. Besides, there is also a false water level phenomenon. How do we understand the false water level?