There are two types of burners for industrial steam boilers, depending on how they control the mixture of air and fuel at the key point in the boiler's operation, which is the generation of combustion.
There are several ways to estimate the thermal efficiency of gas-fired boilers:
1. Direct method: This method involves measuring the amount of fuel consumed and the amount of heat produced by the boiler. By comparing these two values, it is possible to calculate the thermal efficiency of the boiler.
2. Indirect method: The indirect method involves measuring various parameters such as flue gas temperature, ambient air temperature, and fuel consumption, and then calculating the t...
When it is found that the boiler steam pressure can't rise, the first thing we should do is to check whether the water pump of the gas-fired steam boiler works and how much the pressure of the water pump of the gas-fired steam boiler can reach. When installing the water pump of the gas-fired steam boiler, a pressure gauge is installed on the water pump. This is because, if the gas-fired steam boiler does not add water, it can be detected whether it is caused by the water pump.
First, let's explain what an industrial oil-fired boiler is. The industrial oil-fired boilers refer to boilers that use oil as the fuel. Generally, they burn diesel oil, special fuel oil for boilers, heavy oil and waste oil, etc. However, due to the rising price of diesel oil and the problem of supply, they are now turning to fuel oil.
The most obvious use of boilers in any building, including hospitals, is typically heating for the facility. A reliable steam boiler is one of the most economical ways to provide heat across a large space, especially one with multiple floors.
Some kinds of boilers have the problem of energy waste caused by heat loss in the process of steam transmission due to their special structures. To solve this problem, we should properly improve the steam transmission process.
Normally a boiler is provided with two independent sensors for emergency low water level burner cut-outs. So this would never happen. However, if it does, don't take any chances! Shut off the burners immediately!
Before you start raising the level in the boiler you have to find out if any part of the furnace walls has been overheated. If you raise the level over a glowing steel-wall then the boiler might produce more steam than the safety valves can handle and a nasty explosion would be the result.
If the final temperature of feed water doesn’t reach the saturated temperature after being heated by an economizer, (that is, the feed water has not reached the boiling state), we call the economizer as a nonsteaming economizer. Generally, the final temperature is 30-50℃ lower than the saturated temperature.