In the whole drying process, we should pay attention to gradually increasing the temperature instead of burning by raging fire; regularly checking boiler's water level and keeping it within the normal range; keeping the flame balanced in the furnace. In addition, we also should properly open the drainage valve and maintain the water level, regularly record the flue gas temperature to control the rise of temperature and high temperature and keep the temperature within the normal range. In general, under these conditions, boiler’s drying quality can be ensured.
(1)Ensure normal and stable steam pressure, steam temperature and evaporation.
(2)Avoid coking and burner damage; Ensure the safety of the operation of the superheater; Reduce pollution of combustion.
(3)Make the operation achieve the highest economy.
The heating load of an industrial boiler refers to the amount of energy required to generate a certain amount of heat in a specific period, usually measured in British Thermal Units (BTUs) per hour, kilowatts (kW), or megawatts (MW). Essentially, it's the amount of energy needed to heat the water or generate steam in the boiler for industrial processes or heating purposes.
Understanding the heating load is crucial for several reasons:
Boiler Sizing: Accurately determining the heating load is e...
Serious coal leakages in the fire grate of coal-fired boilers can be caused by several factors, each impacting the efficiency and safety of the boiler operation. Understanding and addressing these issues is crucial for maintaining optimal performance. Here are some common causes:
Wear and Tear: Over time, the fire grate components can wear down due to the constant exposure to high temperatures and the abrasive nature of coal. This wear can create gaps through which coal can fall.
Improper Grat...
Proper shutdown procedures are crucial for ensuring the safe and efficient operation of a coal-fired steam boiler. The following steps should be followed when shutting down a coal-fired steam boiler:
1. Reduce the load: Before shutting down the boiler, the load should be reduced to its minimum level. This will help to prevent sudden drops in pressure and temperature, which could cause damage to the boiler and its components.
2. Shut off the fuel supply: The fuel supply to the boiler should be ...
Coking and dust accumulation on heating surface. Whether it is slagging and ash deposition on the water wall of the furnace or ash deposition on the superheater, convection tube bundle, economizer and preheater, the measured thermal resistance of flue gas will increase, and the deterioration of heat transfer will worsen the cooling effect of flue gas, resulting in an increase in the temperature of boiler waste gas.
As a new mature high-efficiency and low-pollution clean coal technology, circulating fluidized bed combustion (CFBC) technology has many advantages that other combustion methods do not have. Circulating fluidized bed combustion is low-temperature combustion, so the NOx emission is much lower than that of pulverized coal furnace, only 200ppm.