Gas-fired boilers use gaseous flammable gases (including liquefied combustible gases) as fuel. These gaseous fuels have relatively higher calorific value and less pollutant emissions, and are gradually becoming popular among corporate users.
During the inspection, the management personnel of the boiler using unit and the monitor of the stoker shall be present to assist in the inspection and provide other materials required by the inspector.
A waste heat boiler is a type of boiler that captures and uses the heat generated by industrial processes, engines, and other sources of waste heat. The core components of a waste heat boiler typically include:
Boiler shell: The outer shell of the boiler that contains the heat exchanger tubes and water.
Heat exchanger tubes: Tubes that carry the hot gases from the waste heat source through the boiler, transferring heat to the water.
Water circulation system: A system of pipes and pump...
An Interlock in the boiler’s control system is a programmed or hardwired condition that forces a device to be in a pre-determined or permissive state before the process can continue.
Depending on design pressure, fuel type, either liquid, gas or solid, all steam boiler require interlocks to sequence the operation and to prevent damage to the boiler. Examples of such devices are High or Low Boiler Drum Water Level, Low Boiler Feed Pump Pressure, High or Low Fuel pressure, High or Low Atomization pressure (oil fired), Proof of Ignition, Proof of Flame, FD and/or ID (solid fuel) Fan Motor Operation or combustion air pressure, Damper or Valve position and High Boiler Steam Pressure as well as O2 and furnace temperature.
The economizer of condensing gas-fired boiler can be installed in the flue of the current CFB boiler, to recovery the energy from the high-temperature flue gas, in order to reduce the fuel consumption. Also, the economizer helps to absorb the air pollutants such as the NOx and sulfur dioxide.
All boiler pipes have been installed and passed the hydrostatic test.
The furnace wall masonry and insulation work have all ended and has been qualified.
The flue gas duct has been installed and insulated, and the induced draft fan has been installed and debugged to be qualified and can be put into operation.
All the thermal and electrical instruments required for boiler drying have been installed and verified to be qualified.
Mortar samples have been placed on both sides of the middle par...
Generally, small gas-fired hot water boilers are between 0.7 MW and 14 MW, and the output of boilers is different, so the prices are different. Different pressures require different techniques, materials and pressures. The higher the pressure, the higher the price.
A 10 tph boiler does not mean that the dead weight of the boiler is 10 tons. The ton of the 10 tph boiler is the heat load unit of the boiler, which is used in engineering, indicating that the rated evaporation capacity of the boiler is 10 t/h.