Boiler output refers to the maximum continuous output of the boiler under rated parameters (pressure, temperature) and certain efficiency. For steam boilers, it is called rated evaporation, and the unit is tons/hour; For hot water boilers, it is called rated heat production, and the unit is MW.
What are the main factors affecting the output of gas-fired boilers? According to the analysis of ZOZEN Boiler engineers, there are many reasons for the insufficient output of gas-fired boilers,
...
Boiler parameters are the main indicators of boiler performance, including boiler capacity, steam pressure, steam temperature, feed water temperature, etc. Boiler capacity can be expressed by rated evaporation or maximum continuous evaporation. Rated evaporation is the amount of steam continuously produced per unit time under the specified outlet pressure, temperature and efficiency. The maximum continuous evaporation is the maximum amount of steam that can be continuously produced per unit time under the specified outlet pressure and temperature.
Manually close the fuel supply valve, stop the combustion, purge after the program enters, until the end of the purge, stop the program such as burning heavy oil, and enter the line sweeping stage before stopping the combustion, and purge with steam or light oil pipe; Generally, steam purging is used when stopping for a long time.
Three-pass steam boilers are so-called because the combustion gases that are produced inside them in the burner go round a circuit that has three parts before leaving it:
The biomass-fired steam boiler is used widely and the biomass belongs to the renewable energy with high thermal efficiency which can be applied by many production enterprises.
The gas consumption of 10 tph gas-fired boiler is related to technical parameters.
Such as heating surface layout, heat preservation effect, heat loss, water capacity, etc. The calculation formula of gas consumption of 10 tph gas-fired boiler is as follows:
=10 tph gas-fired boiler output÷ thermal efficiency ÷calorific value of natural gas
= 6,000,000 kcal ÷ 0.98 ÷ 8,600 kcal / h = 712 m3
Therefore, the gas consumption of 10 tph gas-fired boiler is 712 m3/ h
The gas consumption of the above gas-fired boiler is calculated at full capacity. In practice, the gas consumption changes with the operation load and operation conditions. In addition, if thermal efficiency of the gas-fired boiler is different, the gas consumption is different, too. The higher thermal efficiency is, the lower gas consumption is.
Stack temperature is the temperature of the combustion gases (dry and water vapor) leaving the boiler. A well-designed boiler removes as much heat as possible from the combustion gases. Thus, lower stack temperature represents more effective heat transfer and lower heat loss up the stack. The stack temperature reflects the energy that did not transfer from the fuel to steam or hot water. Stack temperature is a visible indicator of boiler efficiency. Any time efficiency is guaranteed, predicted stack temperatures should be verified.
Stack loss is a measure of the amount of heat carried away by dry flue gases (unused heat) and the moisture loss (product of combustion), based on the fuel analysis of the specific fuel being used, moisture in the combustion air, etc.
Unfortunately, there's no one-size-fits-all answer to this question. The overall cost of purchasing new equipment and implementing a new system will depend largely on a number of factors that vary for each different customer.
While we can't tell you exactly what you should plan to spend, we can give you some information on what will impact the price of the equipment you purchase.
Read on to find out what factors will influence how much you will spend on thermal fluid heating equipment for your plant.