What are the causes and analysis of common failures of steam boilers?
As a kind of equipment that needs to be used continuously for a long time, it is quite common for the boiler to malfunction due to operation errors or environmental quality problems. Today, Let’s discuss the causes, analysis and solutions of common faults of steam boilers.
The causes and analysis of common steam boiler failures mainly include boiler overpressure, water shortage, high drum water level, tube explosion and other problems. After having a preliminary understanding of the steam boiler fault causes, the subsequent safe operation will be more secure.
First of all, it is necessary to prevent the occurrence of boiler overpressure accidents when the steam boiler is running. The overpressure is mainly caused by the rapid increase of pressure, which exceeds the maximum allowable pressure. The pressure is still rising after overpressure. The overpressure protection device should send out an alarm signal to stop supplying coal gas, and the steam temperature will rise, and the flow rate will drop. After overpressure occurs, the combustion should be reduced quickly, and the safety valve should be opened to increase feed water. At the same time, step-down measures should be taken to reduce the temperature in the lower boiler drum, which will endanger the safe operation. When reducing the pressure, don't drop too fast.
Another common reason and analysis of steam boiler failure is that the boiler is short of water. The water level is lower than the safe water level, the water level alarm sounds, the air supply stops when the water level is low, the grate deceleration motor stops running, the superheater steam temperature rises sharply higher than the normal outlet steam temperature and the exhaust gas temperature rises. When there is a serious water shortage, you can smell something burning. From the oven door, you can see the red-hot water-cooling wall, and you can also hear the explosion when the furnace tubes burst. In case of water shortage, emergency shutdown should be taken, instead of blindly adding water to the boiler, and fuel shall be reduced if there is a slight water shortage.
-
WNS series gas-fired (oil-fired) steam boilerLive Chat1-20 t/h0.7-2 MPa
-
SZS series gas-fired (oil-fired) steam boilerLive Chat2-110 t/h1.25-5.3 MPa
-
SZL series coal-fired steam boilerLive Chat6-35 t/h1-2.5 MPa
-
Email us
-
WhatsApp: +86 18861589035
WeChat: +86 13506150756
Live Chat
-
Recently, ZOZEN Boiler successfully delivered a DZW series 20-ton reciprocating grate biomass steam boiler to Kohinoor Mills, a renowned textile enterprise in Pakistan, supporting its transition to green and sustainable production. This collaboration not only underscores ZOZEN’s growing influence in overseas markets, but also highlights its technological innovation and professional service capabilities in the biomass boiler field. ZOZEN Biomass Boiler Supports Pakistan’s T...26 Aug 2025
-
In the global leisure and entertainment product manufacturing sector, Bestway Group is undoubtedly a leading player. With operations spanning over 200 countries and regions, its product portfolio covers around 800 items across leisure, sports, and camping categories. As the company continues to expand its industrial footprint, the Bestway plant in Tien Giang Province, Vietnam, faced an urgent need for a reliable and efficient heat energy supply to support production. ZOZEN Provides a Tailored...19 Aug 2025
-
In 1886, Atlanta pharmacist John Pemberton mixed the first glass of Coca-Cola. What began as a “brown tonic” selling 25 bottles a day has since become a global beverage legend, spanning more than 200 countries with 2 billion servings consumed daily. In Mongolia, its exclusively authorized producer MCS Coca-Cola is expanding into new categories such as iced tea and juices. Powering this strategy is the thermal engine behind the scenes: three 8 t/h WNS series gas-fired steam boilers fr...12 Aug 2025