amount of natural gas needed for 1 ton boiler, the gas consumption of ZOZEN natural gas boilers refreshes the industry record
The natural gas boilers, as the hot selling products on the industrial boiler market, attract the attention of many customers. In order to help enterprises save operating costs, ZOZEN Boiler, as the leading industrial boiler manufacturer, has developed the energy-saving technology and effectively improved the energy-saving and eco-friendly performance of industrial boilers. The gas consumption of ZOZEN WNS and SZS series natural gas boilers has hit a new low. Therefore, what is the amount of natural gas needed for 1 ton boiler?
Before solving the problem what is the amount of natural gas needed for 1 ton boiler, we need to know the calculation formula of gas consumption of gas-fired boilers first. It is,
The gas consumption of gas-fired boilers (per hour) = boiler power*time/calorific value of fuel/calorific value utilization rate of boiler
According to this formula, taking ZOZEN 1 tph WNS series natural gas fired boiler as an example, if the thermal power of 1 tph boiler is 0.7 MW, the calorific value of natural gas is 36 MJ/Nm3, and the boiler thermal efficiency is 98%, so we can get that
ZOZEN amount of natural gas needed for 1 ton boiler (per hour) = 0.7MW×3600s/36MJ/Nm3/98% = 71.4m3/h
However, the above amount of natural gas needed for 1 ton boiler is calculated when the boiler is at full load. In the actual boiler operation, due to different boiler loads and working conditions, the amount of natural gas needed for 1 ton boiler is different as well. Taking ZOZEN 1 tph gas boiler as an example, the technical parameters are as follows:
No. |
Name |
Value |
1 |
Rated capacity |
1 t/h |
2 |
Rated working pressure |
0.7/1 MPa |
3 |
Rated steam temperature |
170/184 ℃ |
4 |
Maximum transport weight |
4 t |
5 |
Maximum transport size |
3.3×1.8×2.1 m |
In conclusion, we can see that amount of natural gas needed for 1 ton boiler is not only closely related to the boiler thermal efficiency, but also can be affected by the actual parameters and conditions in the boiler operation. What's more, amount of natural gas needed for 1 ton boiler is also affected by factors such as boiler manufacturing process, boiler quality and boiler manufacturer. Next, let us see ZOZEN 1 tph WNS series natural gas fired boiler in the actual case.
ZOZEN WNS series natural gas fired boiler is operating at Changzhou Zhaiqiao Gehu Feed Co., Ltd.
With the rapid development of animal husbandry, aquatic products and other aquaculture industries, the demand for pelleted feed is also increasing. The influence of the material base temperature on the moisture absorption of steam-conditioning is enormous. If the base temperature of the mixed material is too high, steam tempering will be affected to a great extent, and the water content of the mixture will change at different times of the year, it has a significant effect on steam tempering. 1~10 tph WNS series condensing gas-fired boilers of ZOZEN boiler are widely used in the feed industry due to its advantages such as high efficiency and high quality steam. Therefore, the Changzhou Gehu Feed at the time of initial construct plant ordered one tph WNS condensing gas-fired boiler at ZOZEN in accordance with the plant scale to provide high-quality steam to participate in production.
Link: https://en.zozen.com/cases/1-tph-wns-condensing-gas-fired-boiler-in-changzhou.html?5xyFrom=site-NT
If you have more questions about the amount of natural gas needed for 1 ton boiler, welcome to consult ZOZEN Boiler.
-
With the development of times, large-scale aquatic product enterprises choose to strengthen the deep processing of aquatic products with the help of industrial boiler systems. This time, ZOZEN Boiler reached the cooperation with Jiangsu Zhengyuan Chuanghui Agricultural Science and Technology Co., Ltd., a key leading enterprise, on the boiler equipment of the aquatic product deep processing project by virtue of ZOZEN's superior boiler solutions.19 Nov 2020
-
From November 15 to 17, 2020 China aerated concrete industry conference (the 40th association annual meeting) was held in Chongqing. ZOZEN Boiler, as an outstanding boiler equipment supplier for the aerated concrete industry, attended the meeting with professional boiler solution and successful project experience, which attracted the attention of many leading enterprises.26 Nov 2020
Find the Right Boiler For You
-
Email us
-
WhatsApp: +86 18861589035
WeChat: +86 13506150756
Live Chat