The safety valve of the boiler refers to the valve on the top of the boiler near the boiler control room. The function of the safety valve is to be opened automatically to exhaust the steam and restore the pressure when the boiler pressure exceeds the specified valve, so as to ensure the safety of boiler pressure-bearing components and steam turbines.
Thermal oil heaters have the characteristics of low pressure and high temperature. They adopt the special manufacturing technology and are equipped with tailor-made flue gas waste heat recovery systems, so they are energy-efficient with higher thermal efficiency than similar products on the market. They also have a high level of automation.
The thermal oil heater, also called the organic heat carrier boiler, is a kind of once-through boiler developed based on the forced circulation design concept. With gas, oil or coal as the fuel and heat conducting oil as the medium, the thermal oil heater adopts the thermal oil pump to force the medium conducting the circulation in the liquid phase. The medium transfers the heat energy to the heating equipment and then returns to the furnace for being reheated. The thermal oil heater has the advantages of high-temperature and low-pressure heating and precise control of the medium.
The thermal oil heater, also called organic heat carrier boiler, provides heat energy for production by heating the heat medium oil. It can realize the high-temperature and low-pressure heating without constant water supply. What are the characteristics of the thermal oil heater?
If the boiler gives overpressure indicator which affects boiler's safe operation, depressurization measures should be taken. However, please pay attention that depressurization can not be too fast. After the overpressure problem of steam boiler is solved, we should check the internal and external parts of boiler to ensure that everything is going well.
From the perspective of atomization mode, there are three kinds of burner used by boiler that are rotating cup atomization burner, pressure atomization burner and medium atomization burner.
1. During the start-up process of the burner, if the burner repeatedly alarms and locks, it should be found out the reason, find the fault and eliminate it, and then press the reset button to inherit the start. Note: The continuous press of the reset button should not exceed 10 seconds
2. If the burner is not successful in one combustion, the natural gas boiler induced draft fan should be restarted, and the second combustion can be started after 5 minutes of ventilation.
3. In the normal operation era, the burner close to the thermal equipment department (such as the connecting flange, etc.) will be very hot, to prevent the formation of burns. Do not place flammable materials in the vicinity to avoid causing fire.
4. During the operation of natural gas-fired boilers, it is necessary to closely supervise the working conditions of hot water circulation pumps and natural gas-fired boiler pressures, natural gas distribution bags, pipeline valves, pressure gauges, flow meters, and water