  • How to select heat medium oil for liquid phase heating systems? 2023-12-01
    Selecting the right heat medium oil (also known as thermal oil or heat transfer fluid) for liquid phase heating systems is crucial for efficient and safe operation. Here are key factors to consider when choosing a heat medium oil: Operating Temperature Range: Different oils have different operating temperature ranges. Choose an oil that can maintain stable thermal properties within the temperature range required by your system. Both the maximum and minimum operating temperatures are important t...
  • What if boiler cannot be ignited in the operation when the pressure is normal? 2023-12-01
    Question details (performance):Fail ignite, normal pressure, has electricity.Answer: Fault reason:1. The ignition transformer is burnt out.2. The high-voltage wire is damaged or detached.3. The clearance is too large or too small, and the relative size of the ignition rod position is wrong.4. Electrode rupture or grounded short circuit.5. Improper spacing. Troubleshooting:1. Replace with a new one.2. Reinstall or replace.3. Readjustment.
  • Why doesn't the gas boiler's motor turn on after pressing the start button? 2023-11-24
    (Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
  • How to estimate thermal efficiency of gas fired boilers? 2023-06-09
    There are several ways to estimate the thermal efficiency of gas-fired boilers:   1. Direct method: This method involves measuring the amount of fuel consumed and the amount of heat produced by the boiler. By comparing these two values, it is possible to calculate the thermal efficiency of the boiler.   2. Indirect method: The indirect method involves measuring various parameters such as flue gas temperature, ambient air temperature, and fuel consumption, and then calculating the t...
  • Can I use artificially softened water in the heating circuit with my boiler? 2023-05-19
    Using artificially softened water in the heating circuit with your boiler can potentially cause issues and is not recommended.   Artificially softened water contains high levels of sodium ions, which can cause corrosion of the boiler and other components in the heating system. This corrosion can damage the boiler and other components, leading to leaks and reduced efficiency.   In addition, artificially softened water can cause problems with water pressure and flow rate, which can i...
  • What is the load tracking of an industrial boiler? 2023-04-27
    Load tracking is an important feature of industrial boilers that helps to optimize their performance and efficiency. Load tracking refers to the ability of a boiler to adjust its output in response to changes in demand.   In an industrial setting, the demand for steam or hot water can vary significantly depending on factors such as production schedules, weather conditions, and other variables. Load tracking allows the boiler to adjust its output to match the changing demand, ensuring that...
  • What is the higher heating value and lower heating value of fuel? 2021-12-31
    The higher heating value of natural gas refers to the total heat released when a specified amount of natural gas is completely burned, including the latent heat of vaporization released by the condensation of water vapor in flue gas into water.   The lower heating value of natural gas refers to the heat released when a specified amount of gas is completely burned, the temperature of combustion products is the same as the initial temperature of natural gas, and the generated steam remains ...
  • How to adjust the combustion of drum boiler? 2021-12-17
    Drum boiler refers to boiler equipment with boiler drum, which is an important pressure component in natural circulation boiler and the connecting hub of the three processes of boiler heating, vaporization and overheating, and plays a connecting role. Water becomes qualified superheated steam in the boiler, which goes through three processes: heating, vaporization and overheating. Heating from feed water to saturated water is a heating process; The vaporization of saturated water into saturated steam is a vaporization process; Heating saturated steam into superheated steam is an overheating process.