  • What are the treatment measures of boiler economizer tube burst? 2022-03-18
    The boiler economizer is a device installed at the lower part of the flue at the tail of the boiler to recover the waste heat of the exhaust gas. It absorbs the heat of the high-temperature flue gas to heat the boiler feed water, reduces the temperature of the exhaust gas of the boiler, saves energy and improves the thermal efficiency of the boiler. Therefore, when using boilers, it is very important to master the correct treatment method of boiler economizer tube burst.
  • What are the six skills of field visit to gas boiler plant? 2022-03-04
    When purchasing the gas-fired boiler, the enterprise will generally require to visit the boiler factory at the later period of boiler procurement. Via visiting the boiler factory, the enterprise can have a comprehensive understanding of the operation process, production scale, product quality details, corporate management level, factory shipment and other information of the boiler factory, and can further understand the service quality of the boiler manufacturer.
  • What is the treatment method of boiler water leakage? 2022-02-11
    1. Water leakage on the inner wall: Water leakage on the inner wall can be divided into three types: boiler leakage, water wall leakage and downcomer leakage. If the leakage holes of boiler barrel and water wall are relatively small, it is ok to use steel with the same steel grade for patching and flaw detection. If the downcomer is leaking, it needs to be replaced. 2. The hand hole leaks: you can re-install it from another angle to see if the hand hole cover is deformed. If it is deformed, you...
  • What are the key contents of periodic inspection of boiler shutdown? 2022-02-04
    1. The defective parts in the last inspection. 2. Whether there are cracks and corrosion on the inner and outer surfaces of boiler pressure components, especially on openings, welds, edges and so on. 3. Whether the pipe wall is worn or corroded. 4. Whether there is any crack, fracture or corrosion at the brace of the boiler and the joint with the pulled element. 5. Whether the expansion port is tight, and whether there is annular crack in the expanded part of the pipe end. 6. Whether the ri...
  • What is the classification of common boiler water? 2022-01-21
    Raw water: refers to water that has not been disinfected and filtered, such as river water, stream water, well water, reservoir water, etc. Feed water: refers to the chemical water delivered from deaerator to boiler by feed pump. Make-up water: Make-up water for boiler is to make up the lost part or externally supplied part after completing a steam-water cycle, so that the boiler can always operate at a safe water level. Recycling condensing water: When the heat energy of steam or hot water i...
  • Why is the boiler not starting up? 2022-01-21
    Water and electricity are not available; Circulating water pump is not running; Water flow switch is different; The 200V 380V power supply is not connected; The valve is not opened; The controller switch is set incorrectly; There is a problem with the controller circuit; There is something wrong with the programmer; Leak detection has not been checked; Air pressure switch impassability; Air pressure switch 1-3 impassability; Overtemperature protection and combustion heat protection;...
  • What is the higher heating value and lower heating value of fuel? 2021-12-31
    The higher heating value of natural gas refers to the total heat released when a specified amount of natural gas is completely burned, including the latent heat of vaporization released by the condensation of water vapor in flue gas into water.   The lower heating value of natural gas refers to the heat released when a specified amount of gas is completely burned, the temperature of combustion products is the same as the initial temperature of natural gas, and the generated steam remains ...
  • Does the boiler need annual inspection? 2021-12-31
    As a kind of special equipment, industrial boiler is special and complex. Complete inspection can ensure the safety operation of the boiler.   The external inspection of the boiler is generally conducted once a year, the internal inspection is generally conducted once every two years, and the hydrostatic test is generally conducted once every six years.   For boilers that cannot be inspected internally, a water pressure test should be conducted every three years. The internal ...