1. If the stop valve of the oil circuit is closed or the feeding of oil is insufficient and the oil filter is blocked, it is necessary to check that the valve in the oil circuit is open, the oil filter works normally and clean the filter screen of the pump.
2. If the oil temperature is low, viscosity is too high or the temperature of the oil fed by pump is too high, the oil temperature needs to be increased or decreased.
3. If the the domestic sewage treatment equipment oil pump breaks down, the oil pump is required to be replaced.
4. If the bearing of fan motor is damaged, it is necessary to replace the motor or bearing.
5. If the fan impeller is too dirty, it is required to be cleaned.
The economizer is a heat exchanger equipment which utilizes heat recovery of flue gases to heat feedwater. It can increase boiler efficiency, reduce the temperature of flue gas and save the fuel by absorbing recovery of flue gases. Besides, the feedwater is heated through the economizer before it is supplied into steam drum to decrease the thermal stress of the steam drum wall caused by temperature difference, which can improve the operating conditions of steam drum and prolong the service life of the steam drum.
A dryback boiler has a rear wall that is lined with refractory, a wetback boiler has a rear wall that is jacketed by water. Because of this fact, wetback boilers typically boast higher efficiency than dryback boilers as the heat from combustion goes directly into heating water instead of refractory. Wetback boilers are also more forgiving with load changes as the reversal chamber of the boiler is totally submerged in water creating an even heat transfer on the intermediate tube sheet to furnace joint.
Today's businesses, regardless of industry, can always do more to improve their sustainability and limit the negative impact their actions have on the environment. There are a number of ways to do this, but one of the best is to use a boiler that's designed to limit the emissions of NOx — one of the most harmful greenhouse gases humans emit into the atmosphere. Aside from being good for the environment, a low NOx boiler can also be good for business.
Boilers with low water volumes require a minimum flow requirement to prevent localized boiling and subsequent heat exchanger damage in a low to zero water flow situation. Minimum flow requirement varies by boiler design. Regardless if a boiler itself has a minimum flow requirement, every hydronic heating system needs to be designed to carry the energy being created away from the boiler to avoid high temperature shut down.
The boiler gas consumption calculation need the following parameters: gas calorific value and boiler thermal efficiency.
Theoretically, the gas consumption of boiler = boiler thermal capacity ÷ (calorific value of gas x boiler thermal efficiency )
Take the 1 tph steam boiler as an example:
= 600,000 cal / (8500Kcal * 0.98) =72m3/h, the 1 tph boiler's gas consumption per hour is about 72 cubic meters.
The main sectors in which industrial steam boilers are used are:
Food, in industrial bakeries or baby food (as an example)
Textile, in rotary dryers
Chemical, for reactors or storage
Pharmaceutical, for the manufacture of medicines
Cosmetics, for the production of perfumes and creams
Stationery and printing, in drying tunnels
The cement industry, for the manufacture of cement parts
Oil, for the storage and distribution of heavy oils
Wood, involved in the process of melanin production
Hospitals and hotels, especially in the laundry and kitchen areas
Automotive and surface treatment, for the final metal finishing.
The primary objective of an industrial boiler is the generation of steam. Steam is generated by heat transfer at a constant pressure. The fluid, which is initially in a liquid state, is heated, produces a variation in its phase and becomes saturated vapour.
This saturated steam can then be used for different applications such as sterilization, fluid heating or electricity generation.