zozen boiler
HomeBoiler tagsboilers in thermal engineering

“boilers in thermal engineering”- related products

  • SZL series biomass-fired hot water boiler 2024-01-18
    The SZL series biomass-fired boiler is a chain grate water tube boiler designed by ZOZEN Boiler based on advanced international technology and experience. It features a horizontal double-drum and vertical layout structure. The boiler consists of two major parts: the upper part is the heating surface and the lower part is the combustion equipment. The front of the boiler body is surrounded by water-cooled walls. The upper part is connected with drum and the lower part is connected with the header to form the combustion chamber, absorbing the radiation heat of the furnace. At the rear end, a convection tube bundle is arranged between the upper and lower drums. After the fuel is burned in the furnace, the high-temperature flue gas is swept across the convection tube bundle for the secondary return, then guided to a separately arranged economizer and finally enters the dust collector before being discharged through the chimney.
  • DZL series coal-fired steam boiler 2019-07-05
    The DZL series quick-installed boiler is a horizontal three-pass water-fire tube chain grate boiler designed for bituminous coal combustion. The boiler features a single drum layout with threaded smoke tubes for convective heating surface, and water-cooled walls on both sides of the drum for radiant heating surface. The combustion equipment adopts a lightweight chain grate, and the boiler is delivered in a complete quick-installed form. The electrical control system enables infinitely variable control of the grate, with alarm and interlock protection for critical parameters.
  • WNS series gas-fired (oil-fired) hot water boiler 2018-07-02
    WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.
  • YQ(Y)W series gas-fired/oil-fired horizontal thermal oil heater 2018-07-02
    The YQW series oil/gas thermal oil boiler adopts a two or three passes round coil structure. The end of the coil tube is tapered, effectively protecting the end furnace wall of the boiler. It is equipped with advanced combustion equipment, and the operation of the boiler is fully automated. The boiler is shipped as a whole and can be put into operation just by connecting the gas (oil) and electricity after it is in place on the site.
  • YQ(Y)L series gas-fired/oil-fired thermal oil heater 2018-07-02
    The YQL series oil/gas thermal oil boiler adopts a two-pass round coil structure. The end of the coil tube is tapered, effectively protecting the end furnace wall of the boiler. It is equipped with advanced combustion equipment, and the operation of the boiler is fully automated. The boiler is shipped as a whole and can be put into operation just by connecting the gas (oil) and electricity after it is in place on the site.
  • YLW series coal-fired/biomass-fired thermal oil heater 2018-07-02
    The YLW series thermal oil heater, with its horizontal layout and square coil tube design, uses a chain grate system for efficient fuel combustion. It incorporates mechanical features for solid fuel feeding, ventilation, and slag removal. During operation, fuel undergoes radiation and convection heat exchanges, proceeds to the waste heat boiler, and subsequently moves to the air preheater and dust remover. The remaining flue gas is then expelled into the atmosphere, resulting in optimal heat transfer and efficient industrial heating.
  • RYQ series molten salt heater 2018-07-02
    ZOZEN's molten salt heaters utilize a heat medium of molten potassium nitrate and sodium nitrite. The heater elevates the molten salt beyond its melting point, enabling a circulation pump to propel it into a flowing and recyclable system. This medium is then further heated within the heat carrier furnace for continuous use. It typically operates between 400-550℃, with a maximum of up to 600℃.