Oil-fired hot water boilers are hot water equipment that is widely used in industrial and civil fields. However, sometimes during use, oil-fired hot water boilers may emit a large amount of white smoke. What is the cause of this?
Firstly, the reason for the oil-fired hot water boiler emitting a large amount of white smoke may be incomplete combustion of the boiler. This may be due to insufficient oil supply, poor oil quality, excessive deposits inside the combustion chamber, and other i...
Thermic fluid heater boilers are widely used in a variety of industries because of their excellent performance and energy efficiency. They offer several benefits over traditional steam boilers, including better temperature control, easy operation, and low maintenance costs. Here are some frequently asked questions about thermic fluid heater boilers:
1, What is a thermic fluid heater boiler?
A thermic fluid heater boiler is a device that uses thermal oil or heat transfer oil to transfer heat fr...
The coal-fired boiler uses coal as fuel. The consumption of coal is a key factor to measure the efficiency of boilers. Under the same condition, the coal-fired boiler with less coal consumption can save more costs for enterprises. However, the coal consumption of coal-fired boilers is related to many factors, such as the efficiency of the boiler, the calorific value of fuel coal and the degree of coal combustion.
The circulating pressure of a thermal oil boiler is generated by the driving of the circulating oil pump to the thermal oil circulation. Generally, the working pressure of the thermal oil pump is 4 ~ 8kg / cm2. Actually, the pressure of the thermal oil pump differs from different working conditions.
What are the factors that affect the maximum pressure of thermal oil heater?
1. Pressure of circulating hot oil pump
The pressure of liqu...
As a new mature high-efficiency and low-pollution clean coal technology, circulating fluidized bed combustion (CFBC) technology has many advantages that other combustion methods do not have. Circulating fluidized bed combustion is low-temperature combustion, so the NOx emission is much lower than that of pulverized coal furnace, only 200ppm.
Ensure that the vent valve on the boiler is open and check there is no pressure in the boiler. Check that the steam stop valve is closed. Check that all the valves for fuel are open, and let the fuel circulate through the system until it comes to the temperature required by the manufacturer recommendation.
The installation contents of boiler body pipeline are as follows:
1) Connection between water supply console and economizer header;
2) Connection between economizer and inlet pipe from economizer outlet to drum;
3) Connection between the main pipe and branch pipe of the drum drop and each lower header of the water wall;
4) Connection of steam guide pipe between each water wall header and steam drum;
5) Connection of superheated steam pipe between outlet header of low-temperature superheater...