The coal-fired boiler uses coal as fuel. The consumption of coal is a key factor to measure the efficiency of boilers. Under the same condition, the coal-fired boiler with less coal consumption can save more costs for enterprises. However, the coal consumption of coal-fired boilers is related to many factors, such as the efficiency of the boiler, the calorific value of fuel coal and the degree of coal combustion.
The circulating pressure of a thermal oil boiler is generated by the driving of the circulating oil pump to the thermal oil circulation. Generally, the working pressure of the thermal oil pump is 4 ~ 8kg / cm2. Actually, the pressure of the thermal oil pump differs from different working conditions.
What are the factors that affect the maximum pressure of thermal oil heater?
1. Pressure of circulating hot oil pump
The pressure of liqu...
As a new mature high-efficiency and low-pollution clean coal technology, circulating fluidized bed combustion (CFBC) technology has many advantages that other combustion methods do not have. Circulating fluidized bed combustion is low-temperature combustion, so the NOx emission is much lower than that of pulverized coal furnace, only 200ppm.
Ensure that the vent valve on the boiler is open and check there is no pressure in the boiler. Check that the steam stop valve is closed. Check that all the valves for fuel are open, and let the fuel circulate through the system until it comes to the temperature required by the manufacturer recommendation.
The installation contents of boiler body pipeline are as follows:
1) Connection between water supply console and economizer header;
2) Connection between economizer and inlet pipe from economizer outlet to drum;
3) Connection between the main pipe and branch pipe of the drum drop and each lower header of the water wall;
4) Connection of steam guide pipe between each water wall header and steam drum;
5) Connection of superheated steam pipe between outlet header of low-temperature superheater...
Generally, small gas-fired hot water boilers are between 0.7 MW and 14 MW, and the output of boilers is different, so the prices are different. Different pressures require different techniques, materials and pressures. The higher the pressure, the higher the price.
A 10 tph boiler does not mean that the dead weight of the boiler is 10 tons. The ton of the 10 tph boiler is the heat load unit of the boiler, which is used in engineering, indicating that the rated evaporation capacity of the boiler is 10 t/h.