zozen boiler
HomeBoiler tagscoal boiler sale

“coal boiler sale”- related faq

  • What are the characteristics of dust collector of coal-fired boiler? 2020-05-29
    The characteristics of dust collector of coal-fired boiler: 1) Separating the particulate matters. The dust collector of coal-fired boiler can effectively separate the big particulate matters with ignition conditions, so as to reduce the obstruction of dust removal system and improve efficiency. 2) Reducing dust. The dust collector of coal-fired boiler can prevent the dust-contained gas from washing the bag to lower the dust concentration of dust-contained gas and extend the service life of filtering bag and pulse magnetic valve. 3) Adopting materials with high quality. The dust collector of coal-fired boiler adopts high-temperature resistant materials that can extend the service life of dust collector. 4) Adopting elastic piston ring. The mouth of filtering bag adopts elastic piston ring to ensure the leakproofness, which is firm and reliable.
  • What are the causes of coal erosion in boiler 2020-05-22
    The causes of coal erosion as distinct from all the other types of erosion are many but from a theoretical point of view are simply high velocity particles impacting and rubbing along the surface of the tubes. The boiler designer minimises this by providing a volume in the furnace and a direction of travel of the coal such that it is burned before it can touch the tubes. This can be defeated by increasing the velocity reducing the combustibility or increasing the mass flow. All of these parameters occur if you reduce the calorific value of the fuel or overload the boiler. If you had no erosion before changing your fuel that is the cause. If you have never had design fuel you dont know if it would have eroded anyway. If it would the cause will be a different reason such as arodynamic flows and aiming of the burner or size of the tartget fireball centre. This is a serious problem and should be dealt with by an experienced expert.
  • How much coal is required to boil water from 60℃ to 90℃ in boiler 2020-05-22
    It could also say, how much heat is required to rais the water temperature from 60 ℃ to 90 ℃. To calculate heat required follow below steps Q= mCp dt Where m - water flow rate (kg/hr) Cp- specific heat of water dt- temperature differences ( 90–60) You will get heat required in kcal/ hr. dividing to Q by fuel GCV and system efficiency you will come to know how much fuel (either it is coal or oil) required to raise the temperature of water from 60 ℃ to 90℃.
  • Why does the efficiency of a boiler increase when pulverized coal is used in its furnace 2020-05-22
    For same energy output when energy input is lesser efficiency increase. When maximum heat energy is generated from coal or losses in heat transfer are reduced efficiency increase. Coal in boulder size is burnt combustion may not be complete. There will be more unburnt coal. As per coal chemistry and as per boiler flue gas velocity as designed best coal size for full combustion is designed. Maximum crushed coal is also not the best. Then there will be more coal dust. According to general design in various technologies pulverized coal give best combustion for fbc boilers. For cfbc boilers generally crushed coal size is 6 mm. When you achieve best combustion mean this is main contributor for increase in efficiency. Boiler design, heat transfer, flue gas velocity, heat losses, are other factors for efficiency.
  • What are the functions of primary air and secondary air in a pulverized coal fired boiler? 2020-05-22
    1.Primary air is used for transportation of fine coal particle from coal mill to boiler floor at different elevations as per requirement. 2.Primary air is used for preheating of moisturised coal in to the coal mill so that minimum energy is required for combustion of the same. 3.As we all know that only 23% oxygen is available in the air by weight. For combustion of huge quantity of coal inside the boiler very high quantity of oxygen is required. This oxygen requirement will be completed by secondary air which is supplied by FORCED DRAFT fans through ducts. This secondary air is coming via air preheater hence its outlet temperature increases this will help in combustion and low heat input is required for combustion of coal.
  • What parameters are critical to the health of a coal-fired boiler? 2020-05-15
    Few parameters critical to health of the Boiler are (4)Heat rate of the Boiler. This is a composite index of many performance indicators. Most of them will appear below. (5)Unburnt fuel in flue gas and at boiler bottom . (6)Flue gas furnace exit temperature. (7)Boiler tube metal temperatures. (8)Oxygen in flue gas. (9)Imbalances in flue gas temperature over a cross section. (10)Spray water consumption in Super heater and Reheater. (11)Heat radiation from insulation. The above all affects the performance of the boiler.
  • What factors are related with the boiler efficiency of a coal-fired boiler? 2020-05-15
    Boiler efficiency is mainly depended on the amount of losses in the system. In high capacity pulverized coal fired boilers the total losses account to about 12 to 14%. Roughly 50% of the losses are governed by fuel properties like hydrogen in fuel, moisture in fuel and ambient air conditions. The other 50% losses are carbon loss and dry gas loss. The best efficiency in the boiler can be achieved if the losses are kept to the minimum. Since 50% of the losses are dependent on the fuel and ambient condition, the best efficiency can be achieved by properly tuning the other 50%, i.e. mainly carbon loss and dry gas loss.
  • What is the requirement of the control system of a coal-fired steam boiler ? 2020-05-15
    The coal-fired steam boiler is a forced circulation high-pressure single-tube DC boiler. Its operation process includes three processes: the combustion process of the fuel, the heat transfer process of flue gas to water and the vaporization process after water absorbs heat. In order to better control these different processes, the control system should make the heat of pulverized coal combustion adapt to the requirements of steam load changes and dryness.
1...4 5 6 7 8 9 10 11