  • What should we do when a CFB boiler encounters a cyclone separator breakdown? 2023-12-29
    When a Circulating Fluidized Bed (CFB) boiler encounters a cyclone separator breakdown, it's important to address the issue promptly and effectively to maintain the boiler's efficiency and safety. Here are steps that should be taken: Immediate Shutdown: First and foremost, shut down the boiler following the standard shutdown procedures. This is crucial to prevent any further damage to the boiler and to ensure safety. Inspection and Diagnosis: Once the boiler is safely shut down, conduct a thor...
  • Why don’t the pumps of coal-fired boilers absorb water? 2023-12-29
    If the pumps of a coal-fired boiler are not absorbing water, it could be due to several reasons. It's essential to diagnose the issue accurately for an effective solution. Here are some common causes: Air Locks in the Pump or Suction Line: If there is trapped air within the pump or the suction line, it can prevent the pump from creating the necessary vacuum to draw water. Low Water Level in the Feed Tank: If the water level in the feed tank is too low, the pump may not have enough water to dra...
  • How to select heat medium oil for liquid phase heating systems? 2023-12-01
    Selecting the right heat medium oil (also known as thermal oil or heat transfer fluid) for liquid phase heating systems is crucial for efficient and safe operation. Here are key factors to consider when choosing a heat medium oil: Operating Temperature Range: Different oils have different operating temperature ranges. Choose an oil that can maintain stable thermal properties within the temperature range required by your system. Both the maximum and minimum operating temperatures are important t...
  • What if boiler cannot be ignited in the operation when the pressure is normal? 2023-12-01
    Question details (performance):Fail ignite, normal pressure, has electricity.Answer: Fault reason:1. The ignition transformer is burnt out.2. The high-voltage wire is damaged or detached.3. The clearance is too large or too small, and the relative size of the ignition rod position is wrong.4. Electrode rupture or grounded short circuit.5. Improper spacing. Troubleshooting:1. Replace with a new one.2. Reinstall or replace.3. Readjustment.
  • Why doesn't the gas boiler's motor turn on after pressing the start button? 2023-11-24
    (Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
  • How to choose a thermal fluid? 2023-08-18
    Choosing a thermal fluid (also known as a heat transfer fluid or HTF) for an industrial boiler application is a critical decision, as it directly impacts the safety, efficiency, and performance of your heating system. Here’s a step-by-step guide to help an industrial boiler buyer or manufacturer choose the right thermal fluid: 1. Operating Temperature Range:Determine the required operating temperature range of your application. Choose a thermal fluid that has a bulk temperature operating ...
  • How to estimate thermal efficiency of gas fired boilers? 2023-06-09
    There are several ways to estimate the thermal efficiency of gas-fired boilers:   1. Direct method: This method involves measuring the amount of fuel consumed and the amount of heat produced by the boiler. By comparing these two values, it is possible to calculate the thermal efficiency of the boiler.   2. Indirect method: The indirect method involves measuring various parameters such as flue gas temperature, ambient air temperature, and fuel consumption, and then calculating the t...
  • What is the load tracking of an industrial boiler? 2023-04-27
    Load tracking is an important feature of industrial boilers that helps to optimize their performance and efficiency. Load tracking refers to the ability of a boiler to adjust its output in response to changes in demand.   In an industrial setting, the demand for steam or hot water can vary significantly depending on factors such as production schedules, weather conditions, and other variables. Load tracking allows the boiler to adjust its output to match the changing demand, ensuring that...