The steam cylinder of the boiler is the main supporting equipment of the boiler, which is used to distribute the steam generated during the operation of the boiler to various pipelines. The steam cylinder of the boiler is a pressure vessel, and its loading capacity and volume should correspond to the supporting boiler.
The boiler water level gauge is a detection instrument that shows the water level of the boiler, and it is one of the important safety accessories of the steam boiler.
Boiler efficiency refers to the percentage of boiler effective utilization heat to boiler input heat per unit time, that is, the percentage of effective utilization heat per standard cubic meter of gas fuel. ZOZEN gas-fired boilers all adopt large furnace design, with the efficiency as high as 98% and NOx emission as low as 30mg/Nm3.
Drum boiler refers to boiler equipment with boiler drum, which is an important pressure component in natural circulation boiler and the connecting hub of the three processes of boiler heating, vaporization and overheating, and plays a connecting role. Water becomes qualified superheated steam in the boiler, which goes through three processes: heating, vaporization and overheating. Heating from feed water to saturated water is a heating process; The vaporization of saturated water into saturated steam is a vaporization process; Heating saturated steam into superheated steam is an overheating process.
When it is found that the boiler steam pressure can't rise, the first thing we should do is to check whether the water pump of the gas-fired steam boiler works and how much the pressure of the water pump of the gas-fired steam boiler can reach. When installing the water pump of the gas-fired steam boiler, a pressure gauge is installed on the water pump. This is because, if the gas-fired steam boiler does not add water, it can be detected whether it is caused by the water pump.
Different boiler types have different weights. The traditional four-ton coal-fired horizontal boiler in China is about 25~30 tons.
ZOZEN Boiler has two series of coal-fired horizontal boilers, which are DZL series and SZL series. The DZL series with the capacity of 4 tons weighs 25 tons, and the SZL series with the capacity of 4 tons weighs 32 tons.
Please do not hesitate to contact us if any.
First of all, don't panic. According to the normal shutdown sequence, check whether the fuel, steam and water valves of gas-fired boiler meet the shutdown requirements.
Secondly, close the surface blowdown valve of the gas-fired boiler to prevent other faults of the boiler. Then, quickly close the main steam valve to prevent the gas boiler drum from losing water.
Thirdly, close the deaerator air supply valve, the main power switch and the natural gas valve. The air inlet of the gas-fired boiler burner should not be blocked to reduce the area of the air inlet, and the room ventilation should not be blocked to avoid the formation of toxic and harmful gases.
Different steam pressures correspond to different steam temperatures.
1. The steam temperature of low-pressure boiler is mostly saturation temperature or not higher than 400℃.
2. The outlet pressure of medium-pressure boiler is 3.8 ~ 5.4 MPa, and the commonly used steam temperature is 450℃.
3. The outlet pressure of sub-high pressure boiler is 5.4 ~ 9.8 MPa, and the common steam temperature is 540℃.