Drying the moisture in the fuel of a biomass-fired boiler is important to ensure efficient combustion and prevent issues such as fuel bridging, clumping, and poor boiler performance. Here are some methods that can be used to dry the moisture in biomass fuel:
1. Sun drying: This method involves spreading the biomass fuel, such as wood chips or sawdust, in a thin layer in a sunny, well-ventilated area. The sun's heat and wind will help to evaporate the moisture in the fuel.
2. Fo...
High exhaust temperature in a biomass-fired boiler can be caused by several factors, including:
1. Insufficient air supply: If there is not enough air supplied to the combustion chamber, the fuel may not burn completely, resulting in high exhaust temperatures.
2. Excessive fuel supply: Excessive fuel supply can overload the boiler, causing incomplete combustion and high exhaust temperatures.
3. Improper combustion: Improper combustion can lead to incomplete fuel burning and high exhaust tempe...
The cleaning process of the rice plant produces husks which are often treated as waste. This waste used as fuel in boiler systems and such boilers called Husk Fired Boiler. The husk fired boiler belongs to the biomass-fired boiler.
ZOZEN Boiler has developed the biomass boiler that use wood chips, straws, palm shells, mesocarp fiber, rice husk and other wastes as fuels in order to achieve zero carbon dioxide emissions. It has developed a reasonable structure of furnace arch, furnace wal...
Low-pressure boilers operate at a lower pressure and reach lower temperatures than high-pressure steam boilers. Water in low-pressure boilers is not heated beyond 250ºF, and the steam pressure does not exceed 15 psi (pounds per square inch).
Biomass-fired boilers need to be shut down for maintenance. Proper maintenance can reduce the damage to the boiler caused by continuous work. Firstly, it is necessary to cut off all power to prevent being struck by lightning. In addition, dust, limescale and carbon deposits should be cleaned up to prevent rust and corrosion of the boiler.
1. If there is air in the pump or suction pipe, the air should be discharged.
2. If the depth of the bottom valve immersed in the water is not deep enough, the depth should be increased.
3. If the rotational speed is too slow or the conveyor belt is too loose, the rotational speed should be adjusted and the conveyor belt should be tightened.
4. If the impeller, suction pipe and bottom valve are blocked by dirt, you should check the pump body and clean the dirt.
5. If the height of water conveyance exceeds the regulations too much, the pump head should be adjusted to the specified range.