Typically, a steam boiler should receive servicing at least once per year. Any kind of safety failure with a boiler can have serious consequences, and so a yearly inspection will help to spot any safety issues that need to be addressed. Servicing your boiler on a regular basis can also help you to save money on repairs. If you spot a problem during routine maintenance, there's a good chance you'll be able to fix it at a much cheaper cost than if the problem goes unnoticed and becomes a larger and more serious issue.
The contents of the inspection for a small boiler may vary depending on the specific type and design of the boiler. However, some common items that may be included in the inspection are:
1. Checking the boiler's overall condition, including the exterior and interior surfaces, pipes, valves, and fittings.2. Inspecting the combustion chamber and burner for proper operation and any signs of damage or wear.3. Examining the water level and pressure gauges to ensure they are accurate and functioning ...
Industrial steam boilers can produce noise for several reasons, including:
1. Combustion noise: Combustion noise is caused by the sound of the flames as they burn the fuel. This noise is typically louder during startup and shutdown, and can be reduced by optimizing the combustion process.
2. Boiler fan noise: Boiler fans are used to supply combustion air and to exhaust flue gases. The noise generated by the boiler fan can be reduced by installing a silencer or adjusting the fan speed.
3. Wate...
The first reason is unreasonable structural design.
In the operation of chain grate boiler, uneven distribution of short coal seams in grate, improper adjustment of coal feeder, unreasonable control of coal seams and poor regulation performance of air supply volume in air chamber will all lead to insufficient burning of coal.
The second reason is unreasonable setting of secondary air.
If the primary wind speed is too high, the air volume is too large, and the air rate is too large, the pulver...
Horizontal steam boiler structure
The horizontal internal combustion boiler has a large-diameter shell, in which a furnace is arranged, and the burner is placed in the furnace to form an internal combustion chamber. Both ends of the furnace are respectively connected with the front and rear tube plates, and the smoke tube is arranged between the front and rear tube plates, so there is no need for bricklaying walls outside the boiler. The structure is mainly composed of boiler shell, furnace, f...
Different steam pressures correspond to different steam temperatures.
1. The steam temperature of low-pressure boiler is mostly saturation temperature or not higher than 400℃.
2. The outlet pressure of medium-pressure boiler is 3.8 ~ 5.4 MPa, and the commonly used steam temperature is 450℃.
3. The outlet pressure of sub-high pressure boiler is 5.4 ~ 9.8 MPa, and the common steam temperature is 540℃.
The flue gas treatment of biomass boiler adopts the pretreatment and deep processing. The deep processing adopts the pulsed jet cloth filter, the waste gas treated by this system can meet the discharge standard stably. The flue gas enters the cyclone dust collector or flame arrestor through the dust removal pipeline.
First of all, the boiler water and steam are two concepts. It is the unit of measurement for boiling water boiler. What is a boiled water boiler? It belongs to the category of normal pressure hot water boiler, which heats the water temperature to boiling state. To ensure safety in use, the top of the boiler is provided with a nozzle communicated with the atmosphere. If steam is discharged automatically, the boiler will always work under normal pressure, so its attribute is normal pressure hot water boiler.