(1)Ensure normal and stable steam pressure, steam temperature and evaporation.
(2)Avoid coking and burner damage; Ensure the safety of the operation of the superheater; Reduce pollution of combustion.
(3)Make the operation achieve the highest economy.
(Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
An Interlock in the boiler’s control system is a programmed or hardwired condition that forces a device to be in a pre-determined or permissive state before the process can continue.
Depending on design pressure, fuel type, either liquid, gas or solid, all steam boiler require interlocks to sequence the operation and to prevent damage to the boiler. Examples of such devices are High or Low Boiler Drum Water Level, Low Boiler Feed Pump Pressure, High or Low Fuel pressure, High or Low Atomization pressure (oil fired), Proof of Ignition, Proof of Flame, FD and/or ID (solid fuel) Fan Motor Operation or combustion air pressure, Damper or Valve position and High Boiler Steam Pressure as well as O2 and furnace temperature.
(1) The boiler and all auxiliary equipment are installed, and all tests such as ball passing test, hydrostatic test and air tightness test are qualified.
(2) All rotating devices, feed water pumps, condensate pumps, salt solution pumps, blowers and induced draft fans for coal conveying, combustion and ash removal are qualified for trial operation.
(3) The fuel and water supply are guaranteed, the steam, water and flue gas piping system are normal, and the connection unrelated to the boiler to ...
In the industrial boiler industry, it is generally divided into four grades: A, B, C and D according to the production qualification license grade, among which, when purchasing boilers, users often consider Grade A boiler manufacturers. What is a grade A boiler?
Power boilers take the chemical energy stored in fuel, convert it to heat energy in the combustion process, and transfer that heat energy to water to produce steam. The transfer of energy from combustion gases to the water and steam is called heat transfer.
Low-pressure boilers operate at a lower pressure and reach lower temperatures than high-pressure steam boilers. Water in low-pressure boilers is not heated beyond 250ºF, and the steam pressure does not exceed 15 psi (pounds per square inch).
1) The entire plant may be purchased as a complete package, only needing securing to basic foundations, and connecting to water, electricity, fuel and steam systems before commissioning. This means that installation costs are minimised.
2) This package arrangement also means that it is simple to relocate a packaged shell boiler.
3) A shell boiler contains a substantial amount of water at saturation temperature, and hence has a substantial amount of stored energy which can be called upon to cope with short term, rapidly applied loads.
*This can also be a disadvantage in that when the energy in the stored water is used, it may take some time before the reserve is built up again.
4)The construction of a shell boiler is generally straight forward, which means that maintenance is simple.
5)Shell boilers often have one furnace tube and burner. This means that control systems are fairly simple.
Although shell boilers may be designed and built to operate up to 27 bar, the majority operat