zozen boiler
HomeBoiler tagstypes of industrial boilers

“types of industrial boilers”- related faq

  • What is the pulverized coal fired boiler? 2020-07-17
    The industrial pulverized coal fired boiler is a new type of industrial coal-fired boiler focusing on pulverized coal combustion technology. The impurities are well removed when the grinding fitness of pulverized coal reaches 200 mesh. The pulverized coal is easy to be ignited and has few ash contents, which can enhance the complete combustion rate and reduce the burden of dust removal.
  • How often should industrial boilers be inspected? 2020-07-17
    The industrial boilers should be inspected regularly for operation safety.
  • What are the three main usages of gas-fired boiler? 2020-07-10
    With the industrial innovation and the advance of science and technology, steam engine is replaced by gas-fired boiler that is a kind of more energy-saving heat production machine. There are three main usages of gas-fired boiler that we need to know in order to better understand the benefits that gas-fired boiler brings to us.
  • What is the function of gas-fired boiler explosion-proof doors? 2020-06-26
    The explosion-proof door of the gas-fired boiler is opened or broken when the combustible gas explosion suddenly increases the pressure, it then releases high-pressure gas to reduce the damage to the gas-fired boiler body and also ensure The function of the gas-fired boiler explosion-proof door is usually reflected when the gas-fired boiler is ignited or running due to improper operation. For instance, the furnace is not purged before ignition, the furnace is still not purged even the ignition cannot successfully be lit, the nozzle is leaking, the fuel is not completely burned, and extinguished failure to cut off fuel quickly, etc. all of them may cause the furnace and tail flue to explode. Installing explosion-proof door for gas-fired boiler is to release the pressure to avoid the accident from expanding and also to ensure the safety of the industrial steam boiler when a slight explosion occurs in the furnace or flue.
  • What if a boiler burner does not function correctly? 2020-06-12
    If the boiler burner fails or is faulty, then your boiler is not going to be able to generate heat efficiently, or in the worst case not at all . As industrial boilers are in almost constant use they are built to be very robust and last for decades, nevertheless they can still have problems with broken burners from time to time. Burner pumps, heads and nozzles can all cause problems but a swift replacement should limit your down time.
  • What are the causes of coal erosion in boiler 2020-05-22
    The causes of coal erosion as distinct from all the other types of erosion are many but from a theoretical point of view are simply high velocity particles impacting and rubbing along the surface of the tubes. The boiler designer minimises this by providing a volume in the furnace and a direction of travel of the coal such that it is burned before it can touch the tubes. This can be defeated by increasing the velocity reducing the combustibility or increasing the mass flow. All of these parameters occur if you reduce the calorific value of the fuel or overload the boiler. If you had no erosion before changing your fuel that is the cause. If you have never had design fuel you dont know if it would have eroded anyway. If it would the cause will be a different reason such as arodynamic flows and aiming of the burner or size of the tartget fireball centre. This is a serious problem and should be dealt with by an experienced expert.
  • What is the calculation method of the circulating water volume of a coal-fired hot water boiler? 2020-04-10
    The coal-fired boiler refers to the boiler uses various types of coal as fuel and converts the heat of coal to steam or hot water. There are generally two calculation methods of the circulating water volume of a coal-fired hot water boiler. One is to calculate the hourly water volume of one square meter and the other is to calculate the design parameter volume of every ton. As for the make-up water volume of this type of boiler, it is usually calculated as 1% to 3% of its total circulating water.
  • How is the dry bottom hopper formed in an industrial boiler? 2020-04-10
    The dry bottom hopper is formed by bending the lower part of the water wall of the front and rear walls inward. The main function is to gather, cool and automatically discharge ash. It is also convenient for the connection and sealing of the lower header and the ash well.
1 2 3 4 5 6