The fuel cost of 10 tph electric boiler: 7,100 kilowatt-hour is multiplied by the local industrial electricity unit price which is nearly 1 RMB, so we can get 1 RMB/kWh and the fuel cost is about 7,100 RMB per hour.
It depends on the system of the gas boiler, the boiler water temperature at 60-90, 90-150 and 70-130 can achieve better energy-saving effect.
Energy-saving devices such as condensers are added to ZOZEN gas-fired hot water boiler. The waste heat is used to increase the water temperature of the gas-fired boiler. The rated inlet temperature is 70℃, and the exhaust gas temperature is reduced, so that the thermal efficiency of the boiler is increased to over 98%.
Combustion system: The combustion system of coal-fired thermal oil heater includes base, grate, furnace, etc. The combustion system of oil/gas heat-conducting oil boiler includes furnace, burner, ignition device, etc.
Oil circulation system: circulating oil pump, oil injection pump, storage tank, expansion tank, etc.
Control system: complete with boiler control box.
Air-smoke system: refers to the system composed of flue gas and air generated by combustion, mainly including induced draft fans...
Heat exchange station and gas boiler room are completely different individuals. Gas-fired boiler room is a place where water (or other medium) is heated with fuel to certain parameters. Gas-fired boiler room is a place where heat source is produced. Its main equipment includes boiler, blower, induced draft fan, circulating pump, and various auxiliary equipment (water treatment), among which boiler is the main part.
The purpose of the heat exchange station is to convert the high-temperature hot ...
In recent years, with the continuous development of new energy technology, China's energy utilization mode has changed from a single form in the past to various forms now. As a green fuel energy, natural gas is widely praised by all levels of society and widely developed and used. Therefore, gas-fired boilers have also become popular boiler equipment in contemporary society.
First of all, don't panic. According to the normal shutdown sequence, check whether the fuel, steam and water valves of gas-fired boiler meet the shutdown requirements.
Secondly, close the surface blowdown valve of the gas-fired boiler to prevent other faults of the boiler. Then, quickly close the main steam valve to prevent the gas boiler drum from losing water.
Thirdly, close the deaerator air supply valve, the main power switch and the natural gas valve. The air inlet of the gas-fired boiler burner should not be blocked to reduce the area of the air inlet, and the room ventilation should not be blocked to avoid the formation of toxic and harmful gases.
Different steam pressures correspond to different steam temperatures.
1. The steam temperature of low-pressure boiler is mostly saturation temperature or not higher than 400℃.
2. The outlet pressure of medium-pressure boiler is 3.8 ~ 5.4 MPa, and the commonly used steam temperature is 450℃.
3. The outlet pressure of sub-high pressure boiler is 5.4 ~ 9.8 MPa, and the common steam temperature is 540℃.
In recent years, the state has stepped up efforts of prohibiting the traditional coal-fired boilers. Major enterprises keep up with the times and purchase various environmental protection boilers. Gas-fired boiler is currently the most popular environmental protection boiler. However, due to geographical limitations in some areas, natural gas is difficult to obtain, or the cost is too high, some enterprises will choose biomass steam boilers.