1) The insufficient heating surface. In the process of retrofit design or improvement, increase the heating surface.
2) The particle size of the fuel is large, the screening characteristics do not meet the requirements, the material concentration in the suspension section is low, and the heat transfer coefficient is small, which makes the output unable to go up, or shows that the bed temperature is high and coal cannot be added. The solution is to improve the fuel preparation system and control...
Boiler output refers to the maximum continuous output of the boiler under rated parameters (pressure, temperature) and certain efficiency. For steam boilers, it is called rated evaporation, and the unit is tons/hour; For hot water boilers, it is called rated heat production, and the unit is MW.
What are the main factors affecting the output of gas-fired boilers? According to the analysis of ZOZEN Boiler engineers, there are many reasons for the insufficient output of gas-fired boilers,
...
Different users have different requirements for boiler configuration. For example, some users need NOx emission less than 30mg/Nm3, and some users only need it less than 80mg/Nm3. The better auxiliary equipment configuration is used, the price of boiler will naturally rise.
Different users have different requirements for the configuration of the whole boiler system, and the brand and quantity of auxiliary machines also affect the price. The better the brand, the more expensive the price. For ex...
The boiler in the bathhouse provides hot water for bathing and heating, and it is an essential product in bathhouses. Generally, it is hot water boiler. With the elimination and banning of coal-fired boilers, many users choose energy-saving and environment-friendly gas-fired boilers. Then how much is a suitable gas-fired boiler?
First of all, we have to determine the boiler plan. Bathhouses mainly need to supply hot water and winter heating all the year round. There are two main options: one se...
Raw water: refers to water that has not been disinfected and filtered, such as river water, stream water, well water, reservoir water, etc.
Feed water: refers to the chemical water delivered from deaerator to boiler by feed pump.
Make-up water: Make-up water for boiler is to make up the lost part or externally supplied part after completing a steam-water cycle, so that the boiler can always operate at a safe water level.
Recycling condensing water: When the heat energy of steam or hot water i...
Water and electricity are not available;
Circulating water pump is not running;
Water flow switch is different;
The 200V 380V power supply is not connected;
The valve is not opened;
The controller switch is set incorrectly;
There is a problem with the controller circuit;
There is something wrong with the programmer;
Leak detection has not been checked;
Air pressure switch impassability;
Air pressure switch 1-3 impassability;
Overtemperature protection and combustion heat protection;...
The boiler drum is connected with downcomer and water wall to form a natural circulation loop. At the same time, the boiler drum receives the feed water from the economizer and delivers saturated steam to the superheater. Therefore, the boiler drum is the connecting hub of the three processes of heating, evaporation and overheating in the boiler.
(1) The mortar in the outer brick joints of the furnace wall can be ground into powder by hand without bonding, which indicates the mortar has been dried.
(2) Use a thermometer to insert 100mm from the outer wall. When the temperature reaches 50℃, it can last for 48h, and the outer wall temperature should be uniform.