The food processing needs the steam or hot water to assist the production and improve the efficiency. Usually, the food plant needs the small tonnage boiler, so the coal-fired boiler is not recommended.
The primary purpose of the boiler is to supply energy to the facility's operations – for comfort heating, manufacturing process, laundry, kitchen, etc. The nature of the facility's operation will dictate whether a steam or hot water boiler should be used. Hot water is commonly used in heating applications, with the boiler supplying water to the system at 120°F to 220°F. The operating pressure for hot water heating systems usually is 30 psig to 125 psig (hydrostatic). Under these conditions, there is a wide range of hot water boiler products available. If system requirements are for hot water of more than 250°F, a high-temperature water boiler should be considered.
A firetube boiler can react very quickly to load changes due to the fact that it has a large volume of stored energy in the form of hot water and steam.
The pharmaceutical sector is an area that requires the highest quality steam for its processes, known as clean steam, instead of other industrial steams. Some processes in this sector even need the highest level of quality - pure steam, which involves even stricter steam purity requirements for use in the sterilization of raw materials and pharmaceutical products at high temperatures.
(1)Ensure normal and stable steam pressure, steam temperature and evaporation.
(2)Avoid coking and burner damage; Ensure the safety of the operation of the superheater; Reduce pollution of combustion.
(3)Make the operation achieve the highest economy.
The thermal efficiency of an industrial boiler is a measure of how effectively the boiler converts the energy contained in the fuel into usable heat. It is typically expressed as a percentage, indicating the ratio of heat output for heating or producing steam to the energy input from the fuel consumed. This efficiency is crucial for understanding the performance of a boiler, as it directly impacts fuel consumption, operational costs, and environmental emissions.
Factors Influencing Thermal Effi...
(Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
The water level of steam drum can reflect the condition between feedwater quantity and evaporation quantity of boiler. If the two parameters maintain a stable balance, the water level also remains unchanged; otherwise, the water level will rise or fall. Besides, there is also a false water level phenomenon. How do we understand the false water level?