A firetube boiler can react very quickly to load changes due to the fact that it has a large volume of stored energy in the form of hot water and steam.
Discharging high-temperature flue gas generated by a biomass-fired boiler efficiently and safely is crucial for boiler operation, environmental compliance, and energy recovery. These gases, if not handled properly, can lead to energy inefficiency and increase the emission of pollutants. ZOZEN Boiler, as a professional industrial boiler manufacturer, incorporates advanced technologies and strategies to manage and utilize high-temperature flue gases from biomass-fired boilers. Here's an overview o...
Selecting a biomass-fired boiler for industrial applications involves careful consideration of various parameters to ensure efficiency, sustainability, and cost-effectiveness. Biomass boilers offer an eco-friendly alternative to fossil fuel-based boilers by utilizing renewable resources like wood chips, pellets, and agricultural waste. When choosing a biomass-fired boiler, pay attention to the following parameters:
1. Fuel Type and Availability:
Type of Biomass: The type of biomass fuel availa...
If the pumps of a coal-fired boiler are not absorbing water, it could be due to several reasons. It's essential to diagnose the issue accurately for an effective solution. Here are some common causes:
Air Locks in the Pump or Suction Line: If there is trapped air within the pump or the suction line, it can prevent the pump from creating the necessary vacuum to draw water.
Low Water Level in the Feed Tank: If the water level in the feed tank is too low, the pump may not have enough water to dra...
(Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
Using artificially softened water in the heating circuit with your boiler can potentially cause issues and is not recommended.
Artificially softened water contains high levels of sodium ions, which can cause corrosion of the boiler and other components in the heating system. This corrosion can damage the boiler and other components, leading to leaks and reduced efficiency.
In addition, artificially softened water can cause problems with water pressure and flow rate, which can i...
Ash accumulation on the heating surface.
The scaling and ash deposition on the water-cooled wall of the furnace and the ash deposition of the superheater, convention tube bundles, economizer and preheater can increase the thermal resistance of the flue gas, weaken the heat transfer, lessen the cooling effect of the flue gas and increase the exhaust gas temperature of the gas-fired boiler.
Too high excess air coefficient.
Under normal circumstances, as the furnace outlet excess...
Power boilers take the chemical energy stored in fuel, convert it to heat energy in the combustion process, and transfer that heat energy to water to produce steam. The transfer of energy from combustion gases to the water and steam is called heat transfer.