Water treatment outside the boiler
Before entering the boiler, raw water is treated with water treatment equipment to remove impurities such as hardness, salinity, dissolved oxygen, etc., so that the feed water can meet the water quality requirements specified by steam boiler. Common water treatment equipment includes sodium ion exchange water softening equipment, ion exchange desalination equipment, reverse osmosis water purification equipment and thermal oxygen removal equipment.
...
The quality of the water used to produce the steam in the boiler will have a profound effect on meeting the objectives such as safe operation, maximum combustion and heat transfer efficiency, minimum maintenance and long working life.
The pharmaceutical sector is an area that requires the highest quality steam for its processes, known as clean steam, instead of other industrial steams. Some processes in this sector even need the highest level of quality - pure steam, which involves even stricter steam purity requirements for use in the sterilization of raw materials and pharmaceutical products at high temperatures.
During the ignition and operation of the chamber combustion boiler fueled by pulverized coal, oil or combustible gas, improper operation can cause the deflagration or secondary combustion in the furnace or flue gas duct, which can further cause the increased pressure in the furnace. When the pressure reaches a certain value, the explosion-proof door is necessary to open automatically to protect the furnace wall of the boiler.
As a professional from ZOZEN Boiler, a leading manufacturer in the industrial boiler market, I understand the importance of maintaining optimal nitrogen oxides (NOx) levels in your boiler systems. High NOx levels not only pose environmental concerns but also can lead to regulatory non-compliance and potential fines. Here’s a comprehensive guide on how to adjust your boiler when NOx levels are high, with a focus on what potential buyers like you should note when considering an industrial bo...
The water level of steam drum can reflect the condition between feedwater quantity and evaporation quantity of boiler. If the two parameters maintain a stable balance, the water level also remains unchanged; otherwise, the water level will rise or fall. Besides, there is also a false water level phenomenon. How do we understand the false water level?
Industrial steam boilers can produce noise for several reasons, including:
1. Combustion noise: Combustion noise is caused by the sound of the flames as they burn the fuel. This noise is typically louder during startup and shutdown, and can be reduced by optimizing the combustion process.
2. Boiler fan noise: Boiler fans are used to supply combustion air and to exhaust flue gases. The noise generated by the boiler fan can be reduced by installing a silencer or adjusting the fan speed.
3. Wate...
An Interlock in the boiler’s control system is a programmed or hardwired condition that forces a device to be in a pre-determined or permissive state before the process can continue.
Depending on design pressure, fuel type, either liquid, gas or solid, all steam boiler require interlocks to sequence the operation and to prevent damage to the boiler. Examples of such devices are High or Low Boiler Drum Water Level, Low Boiler Feed Pump Pressure, High or Low Fuel pressure, High or Low Atomization pressure (oil fired), Proof of Ignition, Proof of Flame, FD and/or ID (solid fuel) Fan Motor Operation or combustion air pressure, Damper or Valve position and High Boiler Steam Pressure as well as O2 and furnace temperature.