Some kinds of boilers have the problem of energy waste caused by heat loss in the process of steam transmission due to their special structures. To solve this problem, we should properly improve the steam transmission process.
Industrial boilers will produce wastes that needs to be treated during the use process, which is what we mentioned of boiler blowdown. What are the methods for boiler blowdown?
1. Regular blowdown
1) The time interval and quantity of discharge depend on the test results of boiler water. It usually do not exceed 5% of the water supply.
2) When the regular blowdown is being made under high load of the boiler, the blowdown of the water-cooled wall header is generally not required to avoid affecting the normal water circulation of the water-cooled wall and forming a tube explosion incident.
2. Continuous blowdown
The amount of blowdown shall be determined according to the test results of the boiler water, and shall be completed by adjusting the needle-shaped angle of the blowdown tube.
Here load means, amount of steam drawn from the boiler. So when the load increases, the specific volume of the steam in the boiler increases reducing the pressure. This inturn demands for more feed water and more amount of fuel to be burnt. So, for any boiler there will be a feed water level control system put in place to measure the water level in drum. As and when the level of water in the drum reduces, the controller sends a signal to the feed water pump to start and stops when the desired water level is reached. This way the steam generation continues to maintain the desired pressure.
A water level sensor fail on a steam boiler is extremely dangerous. The low water cut of should be tested daily. If the sensor fails the boiler could turn all the water into steam, leaving the boiler dry. Without water in the boiler the flame from the burner would heat up the heating surface to extreme temperatures and would crack and damage the inside of the boiler. But that’s not the dangerous part. If water added to boiler while it is extremely hot. Once water touches the extremely hot heating service, water would immediately start to evaporate into steam. When water evaporates it expands 18x it’s original size. The boiler would explode from the sudden increase in pressure from the inside. Some in some cases, boilers that have exploded out of a building and have landed 100s of feet away.
If the boiler burner fails or is faulty, then your boiler is not going to be able to generate heat efficiently, or in the worst case not at all . As industrial boilers are in almost constant use they are built to be very robust and last for decades, nevertheless they can still have problems with broken burners from time to time. Burner pumps, heads and nozzles can all cause problems but a swift replacement should limit your down time.
Missing insulation reduces the system’s efficiency. Insulation helps hold heat in the system, and when the heat can dissipate, more fuel is needed to maintain proper temperature and pressure.
Since missing insulation may not be visible, the best way to detect it is with a thermal imager. If you don’t have a thermal imager as a part of your building’s operations, a plumber or other professional likely will carry one. If your energy costs have increased without a rise in the amount you use the boiler, suspect missing insulation and call to have the system inspected with a thermal imager.
Not inspecting it often enough can lead to minor issues being missed, which can lead to major issues later and possibly injury.
Not checking a boiler system could have catastrophic results in the form of a boiler explosion. Fuel may explode due to unfound problems. The high temperatures generated by the boiler can also cause problems if the water level drops too low and the trip switch fails.
Regular inspections can identify and correct faults in the safety systems that are designed to prevent accidents.
When it comes to regular maintenance, the cost of the inspections and repairs will be dramatically lower than the loss of time and profit from a broken boiler that requires replacing. Don’t let maintenance fall by the wayside. Schedule it at even intervals throughout the year.