During the ignition and operation of the chamber combustion boiler fueled by pulverized coal, oil or combustible gas, improper operation can cause the deflagration or secondary combustion in the furnace or flue gas duct, which can further cause the increased pressure in the furnace. When the pressure reaches a certain value, the explosion-proof door is necessary to open automatically to protect the furnace wall of the boiler.
Boiler is a kind of thermal energy conversion equipment composed of drum and furnace. It uses fuel combustion to heat water into steam or hot water to provide power for production or help auxiliary production. With the continuous improvement of industrial manufacturing technology, boiler's control has also changed from the traditional full manual operation to the present automatic intelligent control.
Selecting a gas-fired boiler for heating a 200,000 m^2 area involves several considerations to ensure efficient, reliable, and cost-effective operation. Here’s a structured approach:
1. Determine Heating Demand
First, calculate the total heating demand of the 200,000 m^2 area. Heating demand varies based on climate, building insulation, usage, and local standards. A rough estimate for moderate climates is 100 W/m^2, but this can vary.
2. Choose Boiler Type
Decide on the boiler type. Fo...
A well designed and operated biomass boiler burning fuel within the specification of the boiler should not produce any smoke, but black smoke may be produced if the fuel is too wet for the boiler. All biomass boilers produce some oxides of nitrogen (NOx), particularly nitrogen dioxide (NO2). While NOx emissions from gas boilers have been reduced significantly in recent years through the use of low NOx burners which burn at a temperature slightly below that at which NOx forms, the nature of biomass combustion, and the need to ensure the complete combustion of wood gases, means that combustion takes place at a temperature where atmospheric oxygen and nitrogen can chemically combine. The better the quality of the combustion control system on a biomass boiler, the lower the NOx emissions will be. In general, biomass boilers produce less NOx than oil boilers. Biomass boilers do not produce any oxides of sulphur (SOx).
Radiation and convection losses will vary with boiler type, size, and operating pressure. The losses are typically considered constant in BTU/hr, but become a larger percentage loss as the firing rate decreases. Boiler design factors that also impact efficiencies of the boiler are heating surface, flue gas passes, and design of the boiler and burner package.
In thermal fluid systems, the choice of materials for valves, piping, gaskets, and other components is critical to ensure the system's integrity, efficiency, and safety. These materials must be compatible with the thermal fluid used, capable of withstanding the operating temperatures and pressures, and resistant to corrosion. As a leader in industrial boiler manufacturing, ZOZEN Boiler emphasizes the importance of selecting the right materials for each component of a thermal fluid system. Below ...
If you notice water dripping from a gas-fired boiler's chimney, it could be due to condensation, which is a common issue in high-efficiency boilers. Here are some key reasons and explanations for this phenomenon:
Condensation of Flue Gases: Modern high-efficiency gas boilers are designed to extract as much heat as possible from the combustion gases before they are expelled through the chimney. This process can cool the gases to a point where the moisture in them condenses into water. This is mo...
(Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.