In the boiler operation,the flue gas discharged from the flue gas duct has a certain temperature. However, the abnormal increase of flue gas temperature in boiler's flue gas duct is usually accompanied with other abnormal phenomena. In this regard, corresponding measures should be taken for adjustment based on the reason analysis.
Once the flameout of gas-fired or oil-fired boiler is confirmed, the boiler should be shut down for inspection and maintenance in time according to the operating regulations. Only after the inspection and test are completed, the boiler can continue to be used.
As a kind of essential equipment applied by many enterprises, condensing boiler is widely favored and recommended for its advanced condensation heat transfer technology, intelligent operation mode and high efficiency in the production. Let us talk about the main significances of using condensing boiler from the following three perspectives.
In the adjustment of boiler operation, on the basis of ensuring safe operation, economic operation must also be achieved to improve boiler efficiency. In general boiler units, the efficiency can basically reach more than 92%, and the total loss is less than 8%. The loss is: exhaust heat loss, generally 5-6%, followed by mechanical incomplete combustion heat loss is less than 1-1.5 %, heat loss and ash slag physical heat loss are about 1%. (Physical heat loss for high ash coal ash residue will be greater).
From the point of view of quantification of indicators, the key to improving boiler efficiency is to reduce smoke loss and heat loss due to incomplete combustion of machinery. Pay attention to the flue gas temperature changes. Excessive flue gas temperature will affect the efficiency of the boiler. Too low temperature may cause low-temperature corrosion of the air preheater. Therefore, it is necessary to strengthen the adjustment according to the load changes during operation. When t
If the boiler burner fails or is faulty, then your boiler is not going to be able to generate heat efficiently, or in the worst case not at all . As industrial boilers are in almost constant use they are built to be very robust and last for decades, nevertheless they can still have problems with broken burners from time to time. Burner pumps, heads and nozzles can all cause problems but a swift replacement should limit your down time.
There are many opinions on the best way to clean a steam boiler. One of the oldest ways is to dissolve a pound of tri-sodium phosphate (TSP) and a pound of caustic soda (lye) in water and pour it into the boiler. Let it cook for a few hours and then drain the boiler. If you can't buy TSP in your town, try a commercial soap called MEX. It works well and will not damage the rubber gaskets found in some boilers. However, before you clean any boiler, check the manufacturer's instructions for their recommendations.
If the following three conditions occur during the burning and flame out process of a gas-fired boiler, the furnace is likely to blow up.
1.The residual gas content in the furnace reaches the ignition limit at the start-up phase of the furnace.
2.The fuel content in the furnace reaches the ignition limit after several times failure of ignition.
3.The fuel is sprayed out because of the halfway extinction of the flame. And, the temperature of the furnace can not meet the spontaneous combustion condition of the sprayed fuel. However, the content of the sprayed fuel reaches the ignition limit.