What are the reasons for the low efficiency of dust collector of the biomass-fired boiler? They are nature of dust, quality of bag and velocity of filtering.
In the boiler operation,the flue gas discharged from the flue gas duct has a certain temperature. However, the abnormal increase of flue gas temperature in boiler's flue gas duct is usually accompanied with other abnormal phenomena. In this regard, corresponding measures should be taken for adjustment based on the reason analysis.
With the continuous development of boiler manufacturing process and technology, fuel types of boiler have also increased, such as various combustible gases, fuel oil, biomass, coal and so on.
As a kind of essential equipment applied by many enterprises, condensing boiler is widely favored and recommended for its advanced condensation heat transfer technology, intelligent operation mode and high efficiency in the production. Let us talk about the main significances of using condensing boiler from the following three perspectives.
The fuel of coal-fired boiler will release some harmful substances after combustion that are harmful to human body, but also pollute the environment. Therefore, the desulfurization treatment is required for coal-fired boiler, including desulfurization before combustion, desulfurization during combustion and desulfurization after combustion. The specific operating methods are different.
When regulating and controlling the coal-fired steam boiler, it will involve the banking-up operation which has a set of operating steps and points for attention. Strictly adhering to the operating steps will be helpful for the more efficient operation of coal-fired steam boiler and can extend its service life at the same time.
A water level sensor fail on a steam boiler is extremely dangerous. The low water cut of should be tested daily. If the sensor fails the boiler could turn all the water into steam, leaving the boiler dry. Without water in the boiler the flame from the burner would heat up the heating surface to extreme temperatures and would crack and damage the inside of the boiler. But that’s not the dangerous part. If water added to boiler while it is extremely hot. Once water touches the extremely hot heating service, water would immediately start to evaporate into steam. When water evaporates it expands 18x it’s original size. The boiler would explode from the sudden increase in pressure from the inside. Some in some cases, boilers that have exploded out of a building and have landed 100s of feet away.
Regular inspections can identify and correct faults in the safety systems that are designed to prevent accidents.
When it comes to regular maintenance, the cost of the inspections and repairs will be dramatically lower than the loss of time and profit from a broken boiler that requires replacing. Don’t let maintenance fall by the wayside. Schedule it at even intervals throughout the year.