(Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
Using artificially softened water in the heating circuit with your boiler can potentially cause issues and is not recommended.
Artificially softened water contains high levels of sodium ions, which can cause corrosion of the boiler and other components in the heating system. This corrosion can damage the boiler and other components, leading to leaks and reduced efficiency.
In addition, artificially softened water can cause problems with water pressure and flow rate, which can i...
Thermic fluid heater boilers are widely used in a variety of industries because of their excellent performance and energy efficiency. They offer several benefits over traditional steam boilers, including better temperature control, easy operation, and low maintenance costs. Here are some frequently asked questions about thermic fluid heater boilers:
1, What is a thermic fluid heater boiler?
A thermic fluid heater boiler is a device that uses thermal oil or heat transfer oil to transfer heat fr...
Question details (Performance) :
1. The vibrating coal grate stops running totally or intermittently.
2. The current of vibrating coal grate motor rises abnormally.
3. The safety clutch of transmission machine of grate or safety pin is broken.
Answer: cause of the problem:
Boiler’s vibrating coal grate is a rotating combustion equipment, due to the bad working conditions, stuck stalling is easily happened and grate failure happens in daily application and ...
In this question, what is the tonnage of a 6 million kcal boiler? Tonnage and 10,000 kcal are the expressions of boiler heat supply or boiler capacity. However, the relationship between different representations is unclear to many users.
Boiler capacity unit
Before the announcement of the equivalent tonnage of 6 million kcal boiler, the common boiler heat supply units in China were summarized:
Kcal/hour (Kcal/h) is a metric unit, which means the heat that the boiler can provide per ...
Prepare relevant technical data, including technical data of boiler manufacture and installation, boiler use registration data, boiler operation records, water quality test records, repair and modification records, accident records and previous inspection reports;
Ensure that the vent valve on the boiler is open and check there is no pressure in the boiler. Check that the steam stop valve is closed. Check that all the valves for fuel are open, and let the fuel circulate through the system until it comes to the temperature required by the manufacturer recommendation.
All boiler pipes have been installed and passed the hydrostatic test.
The furnace wall masonry and insulation work have all ended and has been qualified.
The flue gas duct has been installed and insulated, and the induced draft fan has been installed and debugged to be qualified and can be put into operation.
All the thermal and electrical instruments required for boiler drying have been installed and verified to be qualified.
Mortar samples have been placed on both sides of the middle par...