The quality of the water used to produce the steam in the boiler will have a profound effect on meeting the objectives such as safe operation, maximum combustion and heat transfer efficiency, minimum maintenance and long working life.
Percussive sounds ("banging," "hammering," or "knocking") and vibrations in boiler drums or pipes are serious operational anomalies that demand immediate attention. At ZOZEN, we engineer our coal-fired boilers (like the SZL water-tube and DZL fire-tube series) to minimize these risks, but they can still arise due to operational or system issues. Here are the primary causes and ZOZEN's approach to mitigation:
Common Causes & ZOZEN Solutions:Water Hammer (Steam Condensation Shock):
Cause: Ra...
In the whole drying process, we should pay attention to gradually increasing the temperature instead of burning by raging fire; regularly checking boiler's water level and keeping it within the normal range; keeping the flame balanced in the furnace. In addition, we also should properly open the drainage valve and maintain the water level, regularly record the flue gas temperature to control the rise of temperature and high temperature and keep the temperature within the normal range. In general, under these conditions, boiler’s drying quality can be ensured.
Testing a boiler's energy efficiency is essential for identifying how well it converts fuel into heat and for determining potential areas for improvement. As a professional industrial boiler manufacturer, ZOZEN Boiler emphasizes the importance of regular efficiency assessments to optimize performance, reduce fuel consumption, and minimize environmental impact. Here's a comprehensive approach to testing your boiler's energy efficiency:
1. Understand Key Efficiency RatingsAnnual Fuel Utilization ...
An oil boiler's burner lockout is a common issue that can disrupt heating processes in various industrial and residential settings. This problem occurs when the boiler's control system detects a fault and, as a safety measure, shuts down the burner to prevent further damage or hazards. As a professional industrial boiler manufacturer, ZOZEN Boiler emphasizes the importance of understanding the underlying causes of burner lockouts to ensure timely and effective solutions. Here, we explore the pri...
If the pumps of a coal-fired boiler are not absorbing water, it could be due to several reasons. It's essential to diagnose the issue accurately for an effective solution. Here are some common causes:
Air Locks in the Pump or Suction Line: If there is trapped air within the pump or the suction line, it can prevent the pump from creating the necessary vacuum to draw water.
Low Water Level in the Feed Tank: If the water level in the feed tank is too low, the pump may not have enough water to dra...
If you notice water dripping from a gas-fired boiler's chimney, it could be due to condensation, which is a common issue in high-efficiency boilers. Here are some key reasons and explanations for this phenomenon:
Condensation of Flue Gases: Modern high-efficiency gas boilers are designed to extract as much heat as possible from the combustion gases before they are expelled through the chimney. This process can cool the gases to a point where the moisture in them condenses into water. This is mo...
Using artificially softened water in the heating circuit with your boiler can potentially cause issues and is not recommended.
Artificially softened water contains high levels of sodium ions, which can cause corrosion of the boiler and other components in the heating system. This corrosion can damage the boiler and other components, leading to leaks and reduced efficiency.
In addition, artificially softened water can cause problems with water pressure and flow rate, which can i...