Water and electricity are not available;
Circulating water pump is not running;
Water flow switch is different;
The 200V 380V power supply is not connected;
The valve is not opened;
The controller switch is set incorrectly;
There is a problem with the controller circuit;
There is something wrong with the programmer;
Leak detection has not been checked;
Air pressure switch impassability;
Air pressure switch 1-3 impassability;
Overtemperature protection and combustion heat protection;...
The first technical problem is the reconstruction of boiler body:
The coal-fired boiler is mainly grate firing boiler. For small water-tube hot-water boilers, it may lead to the water temperature at the outlet of the riser exceeding the limit or overheating boiling or even vaporization. For shell-and-tube boilers, the rising flue gas temperature at the furnace outlet will make the working conditions of the tube plate worse, thus causing cracks and leakage of the tube plate.
As a kind of special equipment, industrial boiler is special and complex. Complete inspection can ensure the safety operation of the boiler.
The external inspection of the boiler is generally conducted once a year, the internal inspection is generally conducted once every two years, and the hydrostatic test is generally conducted once every six years.
For boilers that cannot be inspected internally, a water pressure test should be conducted every three years. The internal ...
There are many valves commonly used in atmospheric gas-fired boilers, including gate valves and stop valves of main steam valves, water supply valves, check valves, exhaust valves, etc.
When the water pump is turned on, the pressure signal is transmitted to the on-off valve of the atmospheric gas-fired boiler through the pressure pipe, the valve is opened, and the water circulation is carried out. When the water pump stops, the pressure drops, and the on-off valve is closed slowly to av...
Boiler parameters are the main indicators of boiler performance, including boiler capacity, steam pressure, steam temperature, feed water temperature, etc. Boiler capacity can be expressed by rated evaporation or maximum continuous evaporation. Rated evaporation is the amount of steam continuously produced per unit time under the specified outlet pressure, temperature and efficiency. The maximum continuous evaporation is the maximum amount of steam that can be continuously produced per unit time under the specified outlet pressure and temperature.
At the same water temperature, the larger the excess amount of oxygen scavenger in water, the faster and more complete the chemical reaction. Under the same dosage, the higher the water temperature, the better the deoxidization effect. Under the same deoxidization effect, the higher the water temperature, the smaller the dosage.
With the continuous development of economy, as the main heat energy equipment, industrial boilers are widely used. This article discusses the calculation standard of boiler feedwater enthalpy value.
When the water level is high, the quality of steam will drop. This is because the water level will enter the steam-water separator, and the water will slide out with the steam.