Prepare relevant technical data, including technical data of boiler manufacture and installation, boiler use registration data, boiler operation records, water quality test records, repair and modification records, accident records and previous inspection reports;
Removal of metallic scale and corrosion products generally requires chemical cleaning. Acid or chelant cleaning procedures vary greatly depending on individual circumstances. Chemical cleaning can improve the boiler heat rate and reduce the number of tube failures. It typically improves the stability of boiler chemistry.
The installation contents of boiler body pipeline are as follows:
1) Connection between water supply console and economizer header;
2) Connection between economizer and inlet pipe from economizer outlet to drum;
3) Connection between the main pipe and branch pipe of the drum drop and each lower header of the water wall;
4) Connection of steam guide pipe between each water wall header and steam drum;
5) Connection of superheated steam pipe between outlet header of low-temperature superheater...
All boiler pipes have been installed and passed the hydrostatic test.
The furnace wall masonry and insulation work have all ended and has been qualified.
The flue gas duct has been installed and insulated, and the induced draft fan has been installed and debugged to be qualified and can be put into operation.
All the thermal and electrical instruments required for boiler drying have been installed and verified to be qualified.
Mortar samples have been placed on both sides of the middle par...
Boiler feedwater treatment system includes two parts: pre-desalination system and ion exchange desalination system.
The pre-desalination system includes ultrafiltration system, reverse osmosis system, dosing system, chemical cleaning system, compressed air system, etc.
The ion exchange desalination system includes ion exchange system, acid-base regeneration system, compressed air system, wastewater neutralization treatment system, etc.
The boiler feedwater treatment methods ar...
Different types of oil-fired boilers have different equipment composition. ZOZEN Boiler describes the composition of oil-fired boiler equipment aiming at WNS series and SZS series.
The boiler water film dust remover uses dust-containing gas to impact the inner wall of the dust remover or other special components, and forms a water film in some way, so that the dust in the flue gas is captured by the water film, thus purifying the gas.
Because a certain amount of air is usually dissolved in water, with the increase of temperature, the solubility of air decreases, and the gas is gradually separates from the water in the process of water circulation, and gradually gathers together to form large bubbles and even gas columns. Gas is often produced due to the water supplement, so the boiler exhaust valve must be used to avoid damage to the system.