“rice boiler”- related faq

  • What is the pulverized coal fired boiler? 2020-07-17
    The industrial pulverized coal fired boiler is a new type of industrial coal-fired boiler focusing on pulverized coal combustion technology. The impurities are well removed when the grinding fitness of pulverized coal reaches 200 mesh. The pulverized coal is easy to be ignited and has few ash contents, which can enhance the complete combustion rate and reduce the burden of dust removal.
  • How often should industrial boilers be inspected? 2020-07-17
    The industrial boilers should be inspected regularly for operation safety.
  • What are the causes of flame-out of gas-fired or oil-fired boiler? 2020-07-17
    The flame-out of gas-fired or oil-fired boiler can be caused by many reasons.
  • What is the difference between gas-fired boiler and condensing gas-fired boiler in working principle? 2020-07-10
    In general, gas-fired boiler uses natural gas to heat water in order to provide heat source for underfloor heating and heating radiator, while condensing gas-fired uses condensation technology to recycle the thermal energy from the exhaust gas.
  • What are the three main usages of gas-fired boiler? 2020-07-10
    With the industrial innovation and the advance of science and technology, steam engine is replaced by gas-fired boiler that is a kind of more energy-saving heat production machine. There are three main usages of gas-fired boiler that we need to know in order to better understand the benefits that gas-fired boiler brings to us.
  • How to improve the efficiency of coal-fired boilers to achieve economic operation? 2020-07-03
    In the adjustment of boiler operation, on the basis of ensuring safe operation, economic operation must also be achieved to improve boiler efficiency. In general boiler units, the efficiency can basically reach more than 92%, and the total loss is less than 8%. The loss is: exhaust heat loss, generally 5-6%, followed by mechanical incomplete combustion heat loss is less than 1-1.5 %, heat loss and ash slag physical heat loss are about 1%. (Physical heat loss for high ash coal ash residue will be greater). From the point of view of quantification of indicators, the key to improving boiler efficiency is to reduce smoke loss and heat loss due to incomplete combustion of machinery. Pay attention to the flue gas temperature changes. Excessive flue gas temperature will affect the efficiency of the boiler. Too low temperature may cause low-temperature corrosion of the air preheater. Therefore, it is necessary to strengthen the adjustment according to the load changes during operation. When t
  • What are the causes and treatment methods of slagging on the heating surface of coal-fired boilers? 2020-07-03
    Influencing factors of slagging on heating surface of boiler (1) Ash characteristics of pulverized coal Generally, the softening temperature ST of ash is used as the main indicator of slag formation. Coal with low ash melting point (ST<1200℃) is easy to slag. In addition, the slagging index also includes: silicon ratio, alkali-acid ratio, slagging index, limit viscosity and so on. (2)Aerodynamic characteristics in the furnace Improper air flow organization leads to flame center deviation, and the pulverized coal air flow flame adheres to the wall, causing local slagging of the water-cooled wall; Improper air flow organization, forming flue gas retention vortex area and forming a reducing atmosphere (with CO), reducing the ash melting point and increasing the possibility of slagging. Excess air coefficient: When the excess air in the furnace is too small, a reducing atmosphere may be generated, and the tendency of slagging will increase accordingly. (3)Influence of boiler heat lo
  • What are the safety precautions when operating a gas-fired boiler burner? 2020-07-03
    1. During the start-up process of the burner, if the burner repeatedly alarms and locks, it should be found out the reason, find the fault and eliminate it, and then press the reset button to inherit the start. Note: The continuous press of the reset button should not exceed 10 seconds 2. If the burner is not successful in one combustion, the natural gas boiler induced draft fan should be restarted, and the second combustion can be started after 5 minutes of ventilation. 3. In the normal operation era, the burner close to the thermal equipment department (such as the connecting flange, etc.) will be very hot, to prevent the formation of burns. Do not place flammable materials in the vicinity to avoid causing fire. 4. During the operation of natural gas-fired boilers, it is necessary to closely supervise the working conditions of hot water circulation pumps and natural gas-fired boiler pressures, natural gas distribution bags, pipeline valves, pressure gauges, flow meters, and water