  • What are the operating process and precation of drying for coal-fired boiler? 2024-02-23
    In the whole drying process, we should pay attention to gradually increasing the temperature instead of burning by raging fire; regularly checking boiler's water level and keeping it within the normal range; keeping the flame balanced in the furnace. In addition, we also should properly open the drainage valve and maintain the water level, regularly record the flue gas temperature to control the rise of temperature and high temperature and keep the temperature within the normal range. In general, under these conditions, boiler’s drying quality can be ensured.
  • What are the key contents of periodic inspection of boiler shutdown? 2022-02-04
    1. The defective parts in the last inspection. 2. Whether there are cracks and corrosion on the inner and outer surfaces of boiler pressure components, especially on openings, welds, edges and so on. 3. Whether the pipe wall is worn or corroded. 4. Whether there is any crack, fracture or corrosion at the brace of the boiler and the joint with the pulled element. 5. Whether the expansion port is tight, and whether there is annular crack in the expanded part of the pipe end. 6. Whether the ri...
  • Does the boiler need annual inspection? 2021-12-31
    As a kind of special equipment, industrial boiler is special and complex. Complete inspection can ensure the safety operation of the boiler.   The external inspection of the boiler is generally conducted once a year, the internal inspection is generally conducted once every two years, and the hydrostatic test is generally conducted once every six years.   For boilers that cannot be inspected internally, a water pressure test should be conducted every three years. The internal ...
  • How to adjust combustion during furnace startup? 2021-02-05
    During the start-up of the boiler, attention should be paid to the monitoring of the flame and the following combustion adjustments should be done.
  • What factors have influence on the service life of thermal oil heater? 2020-07-24
    Every customer is concerned about the service life of products he purchases. Extending the service life of thermal oil heater is helpful for reducing customer’s costs and increasing profits. Different existing thermal oil heaters on the market have different service years.
  • How often should industrial boilers be inspected? 2020-07-17
    The industrial boilers should be inspected regularly for operation safety.
  • What are the causes and treatment methods of slagging on the heating surface of coal-fired boilers? 2020-07-03
    Influencing factors of slagging on heating surface of boiler (1) Ash characteristics of pulverized coal Generally, the softening temperature ST of ash is used as the main indicator of slag formation. Coal with low ash melting point (ST<1200℃) is easy to slag. In addition, the slagging index also includes: silicon ratio, alkali-acid ratio, slagging index, limit viscosity and so on. (2)Aerodynamic characteristics in the furnace Improper air flow organization leads to flame center deviation, and the pulverized coal air flow flame adheres to the wall, causing local slagging of the water-cooled wall; Improper air flow organization, forming flue gas retention vortex area and forming a reducing atmosphere (with CO), reducing the ash melting point and increasing the possibility of slagging. Excess air coefficient: When the excess air in the furnace is too small, a reducing atmosphere may be generated, and the tendency of slagging will increase accordingly. (3)Influence of boiler heat lo
  • What are the safety precautions when operating a gas-fired boiler burner? 2020-07-03
    1. During the start-up process of the burner, if the burner repeatedly alarms and locks, it should be found out the reason, find the fault and eliminate it, and then press the reset button to inherit the start. Note: The continuous press of the reset button should not exceed 10 seconds 2. If the burner is not successful in one combustion, the natural gas boiler induced draft fan should be restarted, and the second combustion can be started after 5 minutes of ventilation. 3. In the normal operation era, the burner close to the thermal equipment department (such as the connecting flange, etc.) will be very hot, to prevent the formation of burns. Do not place flammable materials in the vicinity to avoid causing fire. 4. During the operation of natural gas-fired boilers, it is necessary to closely supervise the working conditions of hot water circulation pumps and natural gas-fired boiler pressures, natural gas distribution bags, pipeline valves, pressure gauges, flow meters, and water